Towards Automatic Heart Murmur Characterization from Multi-spot Phonocardiograms
Marcelo Nogueira, Jorge H. Oliveira, Carlos G. Ferreira, Miguel T. Coimbra, Al\'ipio M. Jorge
Key points
From the paper's conclusion- These results indicate multi-spot murmur characterization is feasible with both fusion-based and jointly learned architectures, outlining a path toward automatic, structured murmur reports complementing binary screening.
Abstract
Cardiac auscultation traditionally detects the presence of a heart murmur, but clinicians further characterize it by timing, shape, pitch, quality, and grade. Most automatic phonocardiogram analysis systems stop at binary detection and do not estimate this richer description. In this work, we formulate automatic murmur characterization as five patient-level classification tasks and compare three multi-spot strategies on recordings from the aortic, pulmonary, mitral, and tricuspid auscultation locations. First, classical and deep-learning classifiers are trained independently at each location, and predictions are combined via a maximum-severity late-fusion rule. Second, a synchronous multi-input CNN jointly processes one representative segment per location for a single task. Third, a unified multi-input, multi-output CNN predicts all five attributes from one shared multi-spot representation. Using 735 patients from the CirCor DigiScope dataset with complete four-spot recordings, the best late-fusion configurations reach an unweighted mean sensitivity between 85.56% and 93.81% across the five tasks, with class-specific recalls between 80.00% and 100.00% for every relevant category. The multi-input CNN trails late fusion by 7-16 points depending on the task, while the multi-output model reaches values between 72.59% and 79.40%, estimating all five attributes from one shared representation. We further show that naively balancing training data by adding all minority-class segments degrades patient-level performance under the maximum-severity rule, since it introduces non-representative, noisy segments not filtered by the clustering-based segment selection used for evaluation. These results indicate multi-spot murmur characterization is feasible with both fusion-based and jointly learned architectures, outlining a path toward automatic, structured murmur reports complementing binary screening.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cross-Dataset Generalization in Phonocardiogram Murmur Classification: A Benchmark Study of Domain-Conditional Performance and the Role of Multi-Representation Fusion.Journal of clinical medicine · 2026
- An empirical comparison of deep CNN architectures for heart sound classification from phonocardiogram signals.Frontiers in physiology · 2026
- Selection of Heart Sound Segments for Synchronous Classification of Multi-channel Heart SoundsarXiv · 2026
- A swin transformer with cross-task attention and gating for cardiac murmur detection and grading.Physical and engineering sciences in medicine · 2026
- Multi-feature fusion with bidirectional cross-modal attention for joint multi-task classification of heart sounds.Medical & biological engineering & computing · 2026
- Advancing cardiovascular screening: deep learning-based heart-sound classification using SMOTE and temporal modelingScientific Reports · 2026