Optimal Estimation in Weak Value Amplification with a Position Pointer
Jing-Hui Huang, Jing Zhang, Jian Ge, Lichao Liu, Wang Luo, Xiang-Yun Hu
Key points
From the paper's conclusion- These results demonstrate that the optimal readout depends on the available optical power, detector dynamic range, and technical noise, providing practical guidance for selecting readout strategies in high-precision WVA-based metrology.
Abstract
We experimentally evaluate five estimators for weak-value amplification (WVA) using a position pointer to measure birefringence time delays. Two general approaches are considered: measuring the position shift $\Delta x$ and measuring the probability change $\Delta P_w$ of successful postselection. Specifically, five estimators are investigated: CCD-detected fringe shift $\Delta x$, quadrant photodiode (PDQ) transversal voltage difference (XDIFF), and lock-in amplifier output phase $\eta$ (for $\Delta x$ measurement), as well as PDQ total output voltage (SUM) and CCD-detected average photon number $N_r$ (for $\Delta P_w$ measurement). The measurement precision is characterized by the Allan deviation over a range of input laser powers $P_0$. Generally, measuring the position shift $\Delta x$ yields higher precision than measuring the probability change $\Delta P_w$. At $P_0=0.5$~mW, corresponding to a laser-power-limited regime, direct measurement of the fringe displacement with the CCD achieves a minimum Allan deviation of $(5.30\pm0.10)\times10^{-3}$~as, approaching the corresponding photon-statistical Cram\'er--Rao bound (CRB). At $P_0=50$~mW, corresponding to a detector-limited regime, PDQ detection combined with lock-in demodulation provides the best precision, reaching $(1.80\pm0.06)\times10^{-3}$~as and remaining close to the corresponding CRB. These results demonstrate that the optimal readout depends on the available optical power, detector dynamic range, and technical noise, providing practical guidance for selecting readout strategies in high-precision WVA-based metrology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Breaking the trade-off between sensitivity and dynamic range in weak measurement via dual-mode intensity contrast ratioAPL Photonics · 2026
- Anomalous weak values in a generalized Mach-Zehnder interferometer extracted directly from intensity measurements.NPJ quantum information · 2026
- Dark-field polarization post-selected weak measurement circumvents detector saturation in label-free phase imagingEPJ Quantum Technology · 2026
- Enhanced-sensitivity optical sensing of magnetic fields using postselected amplification and continuous-wave power recyclingarXiv · 2026
- Achieving optimal multiparameter quantum estimation in optomechanicsPhysical Review A · 2025
- Weak Values in Postselected Quantum TrajectoriesarXiv · 2026