A. Qamesh (on behalf of the CMS collaboration), P. D. Dauncey (on behalf of the CMS collaboration), H. A. Krause (on behalf of the CMS collaboration), P. Keskiner (on behalf of the CMS collaboration), S. Mallios (on behalf of the CMS collaboration), R. Shukla (on behalf of the CMS collaboration), N. Tarannum (on behalf of the CMS collaboration)

Key points

From the paper's conclusion
  • We present an optical acceptance test framework specifically designed for the calorimeter, providing comprehensive link and slow-control validation of installed FireFly modules under realistic operating conditions.

Abstract

The CMS Phase-2 upgrade includes a new high-granularity calorimeter. The calorimeter electronics will include around 300 Serenity-S1 FPGA boards that use Samtec FireFly electro-optical modules with a link speed of up to 25 Gbps. General production tests performed by the central Serenity group only validate the high-speed links via copper loopback cables. We present an optical acceptance test framework specifically designed for the calorimeter, providing comprehensive link and slow-control validation of installed FireFly modules under realistic operating conditions. This test combines loopback and board-to-board testing, extended bit error ratio measurements, and continuous module health monitoring within an automated workflow, delivering structured diagnostics and ensuring reliable large-scale system deployment.