OpenULF: A Modular Toolkit Enables Data-Driven Ultra-Low-Field MRI with both Classical and Quantum Sensors
Hanhan Wu, Yuchen Yuan, Weiwen Jiang
Key points
From the paper's conclusion- We identify a SQUID-to-coil crossover near 450 $\mu$T and demonstrate that sensor hardware and ML model capacity can be traded off during system design.
Abstract
Ultra-low-field (ULF) Magnetic Resonance Imaging (MRI) offers a portable, low-cost alternative to conventional scanners by operating at field strengths below 10 mT. At these fields, two sensor technologies compete: quantum SQUID (Superconducting Quantum Interference Device) sensors, which provide high sensitivity but require cryogenic cooling, and classical induction coils, which are inexpensive and room-temperature but produce weaker signals. With conventional physics-based imaging, both suffer from low signal-to-noise ratios (SNR). Data-driven reconstruction has overcome similar limits in related inverse problems, but its use for ULF-MRI has been hindered by a lack of open datasets, benchmarks, and flexible simulators. To close this gap, we present OpenULF, a modular, open-source simulation toolkit that generates paired training data and supports end-to-end machine-learning (ML) reconstruction. OpenULF integrates a Bloch-equation-validated physics simulator, calibrated SQUID and coil receiver models, reconstruction ML networks, and an automated design-space exploration engine. Architecturally, a receiver abstract base class, a typed HDF5 contract that decouples physics from learning, and a resumable sweep engine make sensors, models, and datasets independently substitutable. Using OpenULF, we train 774 models across four anatomical datasets and conduct three design-space explorations. The effectiveness of ML reconstruction depends strongly on the dataset and the sensor. We identify a SQUID-to-coil crossover near 450 $\mu$T and demonstrate that sensor hardware and ML model capacity can be traded off during system design. Sensor and reconstruction choices must therefore be co-designed: the best sensor is set by the dataset and field strength, not by SNR.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MRpro: Open Framework for Model‐Based, Learned, and Quantitative MR Imaging—Application to Low‐Field MRINMR in Biomedicine · 2026
- Physics-based simulation unlocks scaling laws for generalizable MRI reconstructionarXiv · 2026
- Morphometric Brain Networks at Ultra-Low Field: A First Assessment of Feasibility and ReliabilitymedRxiv · 2026
- Topology-Aware Co-Domain Learning for Ultra-Low-Field MRI Enhancement.IEEE journal of biomedical and health informatics · 2026
- Deep learning super-resolution of paediatric ultra-low-field MRI without paired high-field scans.Scientific reports · 2026
- Phase-Constrained Self-Supervised Reconstruction and Denoising for Ultra-High-Resolution MRI.ArXiv · 2026