Evaluating SAM-based and Convolutional Architectures in Thin Retinal Vessel Segmentation: Model Capacity, Computational Cost and Foundation Pre-training
Carlos Eduardo Fontaneli, Cesar Henrique Comin
Key points
From the paper's conclusion- We measured the centerline recall and precision of thin vessels and compared the models while also considering their computational cost and how many epochs they needed to train.
Abstract
In retinal vessel segmentation, plain Vision Transformers (ViTs) are commonly expected to perform worse than convolutional neural networks (CNNs) on thin vessels, for reasons such as their coarse patch tokenization, their weak locality bias and their need for large training sets. Although this expectation is widely shared in the literature, how plain ViTs actually compare with CNNs on thin vessels has not been systematically quantified. We address this question by comparing a model with a plain ViT encoder (MedSAM), a hybrid Transformer (LiteMedSAM) and three CNNs of different sizes on three retinal datasets (DRIVE, HRF, FIVES) and, as a second-domain check, a microscopy dataset (VessMap). We measured the centerline recall and precision of thin vessels and compared the models while also considering their computational cost and how many epochs they needed to train. We found that the pre-trained MedSAM had a centerline recall of thin vessels that was not significantly different from that of the best CNN on all four datasets (-0.6 to +2.5 percentage points). A compact plain ViT obtained through architecture search but trained from scratch did not retain this performance. For pre-trained plain ViTs, our results do not support the expectation that they miss thin vessels, although similar thin-vessel performance can be obtained with much smaller models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Retinal Vessel Segmentation: A Comprehensive Review From Classical Methods to Deep Learning Advances (1982–2025)Advanced Intelligent Systems · 2026
- Prior-Guided Spatial–Frequency Interactive Network for Retinal Vessel SegmentationElectronics · 2026
- Early Dual-path Detail Preservation for Thin Retinal Vessel Segmentation with U-NetInternational journal of intelligent engineering and systems · 2026
- Artificial intelligence for ophthalmic vessel segmentation: from multimodal imaging to clinical translation.Frontiers in medicine · 2026
- SDA-SwinNet: Swin-UNet with Dense Skip and Shift-ASPP for Retinal Vessel Segmentation.Sensors (Basel, Switzerland) · 2026