Optimal Sampling and Noise Mitigation for Vocal Fold Kinematics in High-Speed Videoendoscopy
Harikrishnan Unnikrishnan, Rita Patel, Kevin D. Donohue
Key points
From the paper's conclusion- We characterize these errors, evaluate reduction via Kalman smoothing and temporal interpolation, and determine optimal frame rate bounds relative to pixel excursion, speed quotient (SQ), and open quotient (OQ).
Abstract
Objectives: High-Speed Videoendoscopy glottal area waveforms conflate lateral fold excursion with longitudinal opening, precluding direct estimation of velocity, acceleration, and left-right asymmetry. Displacement waveforms preserve these quantities but are susceptible to spatial quantization and temporal sampling errors. We characterize these errors, evaluate reduction via Kalman smoothing and temporal interpolation, and determine optimal frame rate bounds relative to pixel excursion, speed quotient (SQ), and open quotient (OQ). Methods: Sampling theory was used to derive analytical frame-rate bounds required for kinematic feature fidelity. Kalman smoothing was compared with FFT-based denoising, paired with sinc or spline interpolation. Interpolation was evaluated on 4000 fps recordings (N=55) downsampled and reconstructed. A 16000 fps dataset (N=12) served as reference for noise reduction across 2000-8000 fps downsampled waveforms evaluated on peak displacement, velocity, OQ, and SQ. Results: Sinc interpolation yielded lower median mean absolute error than spline (0.29 vs 0.52 pixels), with 85% of recordings (47/55) versus 45% (25/55) below 0.5 pixels. For kinematic feature estimation (N=12), Kalman-sinc outperformed FFT-sinc in 75% of feature-by-frame-rate pairings. Conclusion: Computing kinematic features without artifacts requires joint consideration of temporal and spatial resolution. Kalman-sinc preprocessing at 8000 fps is recommended for velocity and SQ measures. Peak lateral displacement can be measured at 2000 fps, while OQ requires 4000 fps for typical spatial resolutions (9-14 pixels maximum excursion). Pixel excursion should be reported alongside kinematic measures to contextualize data reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of reduced frame rate on kinematic analyses in videofluoroscopic swallowing studiesJournal of Exercise Therapy and Rehabilitation · 2026
- From MNH to the Friedman--Komogortsev Method---which changes improve eye-movement classification?arXiv · 2026
- Real-time estimation of high-resolution flow fields and reduced-order coordinates from event-based imaging velocimetry.Experiments in fluids · 2026
- Vibratory Characteristics and Quantitative Parameters of Laryngeal Dystonia: A Scoping Review of High-Speed Videoendoscopy Studies.World journal of otorhinolaryngology - head and neck surgery · 2026
- VibraGlot: Contactless Vocal Disorder Screening via mmWave Neck-Surface Vibration SensingProceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · 2026
- Cardiovascular High Frame Rate Echo-Particle Tracking Velocimetry.IEEE transactions on ultrasonics · 2026