Calorimetry as inference: the information content of particle showers and the limits of energy measurement
Wonyong Chung
Key points
From the paper's conclusion- We measure the ladder above that rung on Geant4 truth records of hadronic showers in copper, from the dissipated-energy sum to time-, position- and multiplicity-resolved records, with estimators validated on exactly solvable toy models.
Abstract
A calorimeter does not measure the energy of a particle, it infers it from the record the absorption process leaves behind. Energy conservation writes every event as an accounting ledger, E = E_dis + E_B + E_esc + E_nu, of which only the dissipated component contributes to signal, so resolution is limited by how well the record of the dissipation constrains the missing entries. We formalize this: records form a lattice on which information is monotone; thinning a Poisson record scales Fisher information exactly by the retention; clustered records read out as sums cost the 1/(1+cv^2); and the quadrature budget a/sqrt(E) (+) b is the floor of every summed readout. The "ultimate limits" of hadronic calorimetry are identified as the first rung of a ladder, the residual spread of the invisible energy around a single correlated observable. We measure the ladder above that rung on Geant4 truth records of hadronic showers in copper, from the dissipated-energy sum to time-, position- and multiplicity-resolved records, with estimators validated on exactly solvable toy models. The achieved full-record value, model-conditional, is about 5.5%/sqrt(E) (+) 0.3% over 20-100 GeV, a factor 1.7-1.9 below the canonical one-functional construction on the same events (1.29% vs. 2.14% at 20 GeV). Under retrained high-precision neutron transport it moves from 1.29% to 1.30%, the dissipated-energy sum by 7%, and the gain from time structure becomes 0.17% in place of 0.28%. Dual-readout supplies the largest share of the information. Shower shape is next, almost entirely longitudinal, saturating at about one interaction length. Time structure adds nearly as much with or without shower shape, and stopped-muon neutrino losses set an estimated floor of 0.99% at 20 GeV. Every readout dimension has a measured information exchange rate, separating what new hardware can buy from what better algorithms can recover.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Just CaloCHILL: fast hadronic shower generation in a learned latent spacearXiv · 2026
- Physics-constrained generative inference of sub-crystal electromagnetic shower structure in a segmented calorimeterThe European Physical Journal C · 2026
- Data-quality monitoring of luminosity blocks with ATLAS Open Data: an open benchmark and a learned within-run detectorarXiv · 2026
- Learning to Calibrate Jet EnergiesarXiv · 2026
- Is the learner or the summary the limit? Auditing machine-learning energy reconstruction for air-shower arrays on KASCADE and GRAPES-3arXiv · 2026
- Hybrid Quantum-Classical Sequence Models for Sample-Efficient Energy Regression in Simulated Calorimeter ShowersarXiv · 2026