Real-Time Requirements and Transferability in Compton Imaging: From the Detector Chain to the Application
F. Albiol, Elena Larrea Estrelles, Salvador Tortajada, Luis Caballero, Jose Escalante, Alberto Albiol, Jose Luis Leganes-Nieto
Key points
From the paper's conclusion- We give the quantities a report must contain for a third party to judge whether a method fits an application it was not built for.
Abstract
Compton cameras are proposed for tasks whose value decays with delay: verifying a range during irradiation, guiding an intervention, characterising an inaccessible volume, surveying a band no telescope covers. Whether a device can serve such a task is settled by the composition of its whole chain, while the literature that would answer the question is organised by stage -- so claims made at application level routinely rest on evidence obtained at component level. This review walks that chain, asking at each stage what binds first and what a reader can determine from the published text, and then asks what governs whether a capability transfers between groups and between application domains. The evidence is of two kinds: 83 full texts scored in context against defined markers, and, for five application domains measured alike, the size of the receiving literature, of the need it states, of the incumbent and of deployment commitment. Performance is reported at one operating point in 65 of 83 full texts, with count rate swept in none: the field reports values where transfer requires gradients. An accelerator is used in 39 works and a learned model in 31, while separability is discussed in 28, a memory footprint given in 9, and the cost of a precomputation or the inference time of a model in none. Across domains, neither the size of the receiving literature, nor of the incumbent, nor of the stated need orders the domains as deployment commitment does, while whether the incumbent can serve the task at all, and how many domain boundaries the output must cross, do so consistently. The distribution of publication is close to the inverse of the distribution of deployment commitment. We give the quantities a report must contain for a third party to judge whether a method fits an application it was not built for.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Camera-Based Single-Volume, Monolithic Compton CameraarXiv · 2026
- Roadmap: Image reconstruction in emission tomography for the era of fast Monte Carlo simulationarXiv · 2026
- Comparison of spectral performance of three dual-energy CT scanners equipped with a deep-learning image reconstruction algorithm and one photon counting CT scanner: A phantom studyDiagnostic and Interventional Imaging · 2025
- Three-dimensional gamma-ray imaging and mapping using the transportable GRI+ Compton cameraJournal of Instrumentation · 2026
- Photon-Counting Computed Tomography in the Era of Precision Medicine: Technological Advances, Artificial Intelligence Integration, and Multidisciplinary Clinical ApplicationsInternational Science Journal · 2026
- Toward Broader Clinical Adoption of Photon-Counting CT: Where We Stand According to High-Impact LiteratureRadiology · 2026