Laboratory Coupled Loading Method for Root-Layer Separation Deterioration at Earthen Heritage Sites
LIU Hong, HUO Ming, PEI Qiangqiang, CHYNARBEK Zholdoshov
Key points
From the paper's conclusion- The results indicate that the method can reproduce the key hydrothermal conditions associated with root-layer separation deterioration under controlled laboratory conditions without replicating the complete natural meteorological history.
Abstract
ObjectiveRoot-layer separation in vegetation-covered earthen heritage deteriorates gradually under natural conditions through coupled thermal, hydraulic, and structural processes. Reproducing long-term meteorological records directly in the laboratory is inefficient and may obscure the processes most relevant to deterioration. In this study, we aimed to establish a controllable laboratory loading method that translates the natural freeze-thaw period at the Xanadu Site into repeatable thermal and snowmelt loading while preserving the key environmental processes acting at the interface between the root layer and the underlying rammed earth. The method was designed to reproduce the sequence and interaction of these processes rather than the absolute deterioration rate of the heritage fabric, providing an experimental basis for subsequent mechanism studies and the evaluation of conservation measures.MethodsField investigations of deterioration, hydrothermal monitoring of a full-scale experimental wall, and long-term meteorological statistics were combined to identify the processes governing deterioration. The heritage wall, field experimental wall, and indoor model wall represented three related but nonequivalent scales. The field wall was constructed using local soil and a rammed-earth technique comparable to that used at the site, with original turf containing a root-rich layer placed on top. Temperature and volumetric water content were monitored near the surface, around the lower boundary of the root-affected layer, and within the underlying rammed earth. The indoor model consisted of a lower rammed-earth body and an upper turf layer. The rammed-earth body had a bottom width of 1.50 m, a top width of 1.10 m, and a height of 1.19 m. It was compacted in 17 layers, each 7 cm thick. The turf layer was approximately 10-15 cm thick. The model was cured at room temperature for 6 months before loading. The transition between the turf layer and the underlying rammed earth was simplified as an equivalent sensitive interface to facilitate observation of differential hydrothermal responses under controlled conditions.Four controlling variables were identified from the field observations: temperature fluctuations around 0 °C, snowfall and snowmelt water supply, cumulative freeze-thaw action, and structural heterogeneity of the root layer. The natural freeze-thaw period was then translated into three sequential laboratory loading programs, without treating them as direct equivalents of separate natural periods. Loading sequence 1 alternated between -6 °C for 4 h and 6 °C for 2 h and was repeated four times. Loading sequence 2 maintained a temperature of -15 °C for 24 h. During this sequence, artificial snow was applied in five increments until a snow cover approximately 30 cm thick formed on the model surface. Loading sequence 3 alternated between -6 °C for 2 h and 7 °C for 4 h and was repeated five times to promote snowmelt infiltration and subsequent hydrothermal redistribution. Based on the characteristic heat-conduction time scale, the 24 h field temperature process was compressed into a 6 h laboratory cycle. This compression defined the experimental time scale; however, was not intended as a direct conversion of the natural deterioration time. Chamber temperature, interface temperature, volumetric water content, and surface images were recorded throughout the coupled loading process. Feasibility was assessed based on the execution of the loading programs, the formation of snow cover and realization of snowmelt, the sensitivity of the interface, and the correspondence between field and indoor hydrothermal responses.Results and DiscussionsThe environmental chamber generally reproduced the programmed temperature boundary, establishing distinct transitions between subzero and above-zero conditions. Artificial snowfall produced a continuous snow cover on the turf surface, which gradually melted during above-zero temperature loading. These observations demonstrated that snow cover and snowmelt water supply could be combined with programmed temperature control in a repeatable manner. At the equivalent sensitive interface, temperature variations were substantially smoother than those in the chamber and exhibited a clear lag during cooling and warming. This response indicated that external thermal disturbances reached the root-layer boundary; however, were buffered by the thermal inertia of the layered soil system and surface cover. Volumetric water content at the interface generally decreased during the low-temperature portion of each cycle and increased after warming and snowmelt. Because dielectric measurements of water content can be affected by freezing and ice formation, moisture data were interpreted primarily as relative temporal changes rather than as absolute measures of total water content.For the three corresponding intervals associated with loading sequences 1-3, the interface-temperature variation amplitudes of the field experimental wall were 14.6, 28.7, and 2.9 °C, respectively, compared with 9.2, 4.5, and 1.8 °C for the indoor model wall. The corresponding volumetric water content variation amplitudes were 9.8%, 20.5%, and 4.6% for the field wall and 0.6%, 0.4%, and 0.5% for the indoor model. The larger amplitudes observed in the field reflected the longer exposure duration and the combined effects of solar radiation, wind, natural snow cover, evaporation, freezing-induced water migration, and wall-scale thermal inertia. The smaller amplitudes in the indoor model resulted from the shorter loading duration and controlled thermal and water boundaries. Accordingly, equality of absolute amplitudes was not used as a similarity criterion. Instead, the assessment was focused on whether both systems developed identifiable hydrothermal responses at the transition between the root layer and the underlying rammed earth and preserved the sequence of external thermal disturbance, snow accumulation, snowmelt water input, delayed heat transfer, and moisture redistribution at the interface. The observations demonstrated that the laboratory model reproduced the key hydrothermal processes associated with root-layer separation deterioration, although it did not reproduce the natural time scale or quantitative deterioration rate observed at the heritage site.ConclusionsA coupled loading method was developed by identifying and reorganizing the dominant environmental processes occurring during the natural freeze-thaw period. Temperature fluctuations, snowmelt water supply, cumulative freeze-thaw action, and root-layer heterogeneity were incorporated into three sequential laboratory loading programs combining programmed temperature control, artificial snowfall, and snowmelt infiltration. The method established a controllable external boundary and produced delayed temperature responses and loading-dependent moisture redistribution at the equivalent sensitive interface. Field and laboratory responses differed in amplitude because of differences in scale, exposure duration, boundary conditions, and interface structure. However, both systems exhibited process-level correspondence at the sensitive interface. The results indicate that the method can reproduce the key hydrothermal conditions associated with root-layer separation deterioration under controlled laboratory conditions without replicating the complete natural meteorological history. It provides a repeatable experimental basis for further investigation of deterioration mechanisms, identification of response thresholds, comparative evaluation of conservation measures, and cross-scale interpretation of the behavior of vegetation-covered earthen heritage under seasonal freeze-thaw conditions.
Read the paper
No full-text link yet
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thermo-hydro coupling characteristics and evolutionary interpretation of the “Crust-Loose-Base” ternary structure in arid earthen sitesnpj Heritage Science · 2026
- Mechanisms of Tree Root Effects on Ancient City Wall Structures Investigated Through Integrated Infrared Thermography and Visible Light ImagingHeritage · 2026
- Hydro-Thermo-Mechanical Response and Deformation Characteristics of Reinforced Soil Retaining Walls in Seasonally Frozen Regions Under a Sequential Freeze-Thaw-Dynamic Loading Path.Materials (Basel, Switzerland) · 2026
- Low-Disturbance Prediction of Scaling-Off Deterioration on the Shaded and Sunward Sides of Earthen Heritage Sites Based on Comprehensive Assessment of Weathered-Layer CharacteristicsCoatings · 2026
- Soil-Structure Interface Behavior Under Unsaturated and Drying Conditions: Experimental Advances and Research GapsGeotechnics · 2026
- Staged Wetting and Contact Stress Redistribution Beneath a Segmented Hydraulic Structure on Collapsible LoessEng · 2026