Key points
From the paper's conclusion- We also demonstrate that the nanofilm with a 72 nm Al layer achieves a repeatability better than 150 mK above 175 K, and the frequency resolution of 1 Hz corresponds to a temperature resolution of ~5 mK.
Abstract
Non-invasive thermometry is highly desirable in cryogenic experiments to avoid the self-heating inherent in conventional sensors. In previous work, temperature was probed via the vibrational eigenfrequency of a suspended single-layer SiNx nanofilm. However, the turning point of the frequency-temperature curve limited the usable measurement range. Moreover, the slow thermal response confined measurements to a stepwise protocol with only discrete temperature points. Here, we show that these limitations can be overcome with a suspended bilayer SiNx/Al nanofilm, whose temperature-dependent vibrational eigenfrequency provides a monotonic, continuous, and repeatable temperature readout. The frequency-temperature dependence is governed by the mismatch between the effective coefficients of thermal expansion (CTE) of the bilayer and the substrate, which makes the turning point tunable through the thickness ratio of the two layers. Over the 90 K to 300 K range, we characterize three bilayer nanofilms with different Al layer thicknesses and show how the turning point shifts with the thickness of the Al layer. For the sample with 72 nm Al, the turning point is pushed beyond 300 K, yielding a monotonic negative temperature coefficient over the entire 90 K to 300 K range. Combining a thin Al layer on the SiNx film with improved thermal anchoring of the chip shortens the thermal response to below 1 s, enabling continuous frequency tracking at a ramp rate of 3 K/min. We also demonstrate that the nanofilm with a 72 nm Al layer achieves a repeatability better than 150 mK above 175 K, and the frequency resolution of 1 Hz corresponds to a temperature resolution of ~5 mK.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optical Detection of Coefficient of Thermal Expansion via Frequency Tracking at Cryogenic TemperaturesarXiv · 2026
- Thermal Endurance of Suspended Thin-Film Lithium Niobate up to 800 ∘C.IEEE transactions on ultrasonics · 2026
- Compact thermo-optic switch based on graphene-silicon nitride nanobeam cavity.Optics express · 2026
- Temperature-Resolved Electrical Transport Response of ZrO x N y Thin Films under Alternating Electrical PerturbationACS Applied Electronic Materials · 2026
- Waveguide-based measurement of the silicon nitride refractive index and thermo-optic coefficient from the visible to the near-infraredAPL Photonics · 2026
- Temperature-insensitive nanomechanical resonators in CMOS oxides.Nature communications · 2026