Evidence-Guided Selection of Retinal Vessel Segmentation Pipelines: A Cross-Dataset Benchmark of Performance, Structure, Failure Modes, and Reproducibility
Ruoyu Yan, Yuejia Liu, Shixin Xu, Xiaoyan Li, Xi Luo, Yuhui Deng, Huaxiong Huang
Key points
From the paper's conclusion- The results support task-conditioned, benchmark-relative pipeline selection rather than a single universal ranking and highlight the need to validate the selected pipeline on the intended target domain.
Abstract
Retinal vessel segmentation is widely used in retinal image analysis, yet model selection based only on aggregate overlap scores can overlook structural fidelity, cross-dataset robustness, and application-specific error costs. We evaluated five executable binary vessel-segmentation pipelines (FSG-Net, SA-UNetv2, DCP-1024, GAVE, and FR-UNet) on 244 images from six public datasets using pixel-level agreement, cross-dataset stability, thin-vessel retention, structural metrics, error composition, and available computational evidence. Results were aggregated with equal weighting across datasets. No pipeline was optimal in every setting. FSG-Net achieved the highest equal-dataset mean Macro-F1 (0.77), IoU (0.63), clDice (0.83), and Skeleton F1 (0.78), whereas SA-UNetv2 achieved the highest mean sensitivity (0.85) and Thin-Vessel Sensitivity (0.63). Differences across datasets were often larger than those among the leading pipelines, and errors shared by all five methods were concentrated near annotated vessel boundaries and faint peripheral vessels. In an ancillary analysis on 45 HRF images, segmentation masks were converted into 11 ring-wise vascular features for leave-one-out classification. Controlled perturbations showed that local mask errors can be amplified in downstream features, while targeted stabilization reduced sensitivity for five features. The results support task-conditioned, benchmark-relative pipeline selection rather than a single universal ranking and highlight the need to validate the selected pipeline on the intended target domain.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cross-Dataset Generalization of Deep Learning for Retinal Vessel Segmentation in Fundus Images: External Evaluation from DRIVE to CHASE_DB1.Bioengineering (Basel, Switzerland) · 2026
- Toward Modality-Aware Preprocessing for Deep Learning-Based Blood Vessel SegmentationBioMedInformatics · 2026
- BGAFS-UNet: adaptive feature fusion via boundary guided sampling for retinal vessel segmentationFrontiers in Computer Science · 2026
- Retinal Vessel Segmentation: A Comprehensive Review From Classical Methods to Deep Learning Advances (1982–2025)Advanced Intelligent Systems · 2026
- Prior-Guided Spatial–Frequency Interactive Network for Retinal Vessel SegmentationElectronics · 2026
- A Stage-Wise Explainable Pipeline for Arteriolar-to-Venular Ratio Estimation and Retinopathy ScreeningarXiv · 2026