Comparing local and global optimization reveals untapped hybrid potentials for machine learning-based inverse planning
Tim Ortkamp, Florian Leininger, Zhongxing Liao, Niklas Wahl, Ali Ajdari
Key points
From the paper's conclusion- The authors compared two open-source frameworks for ML-based inverse planning: OptiCL (global mixed-integer optimization via constraint learning) and pyanno4rt (local nonlinear optimization via end-to-end differentiation).
- Across eight head-and-neck (HN) photon cases and seven lung proton cases, mean differences in dose were small: for HN cases, -0.16 Gy [-0.37, 0.06] (parotid) and -0.00 Gy [-0.01, 0.00] (PTV); for lung cases, -0.52 Gy [-1.10, 0.06] (total lung) and -0.04 Gy [-0.07, -0.01] (PTV). Mean NTCP differences were -0.08 p.p. [-0.49, 0.33] (HN) and -1.73 p.p. [-2.68, -0.77] (lung).
- OptiCL tended toward lower OAR doses and predicted NTCP but required higher wall-clock runtime. Hybridization of the decision tree-based HN plan eliminated 80% of binary decision variables without compromising plan quality.
Abstract
Machine learning (ML) models for normal tissue complication probability (NTCP) can be embedded directly into inverse treatment planning, but the resulting optimization problems are generally nonconvex, and the choice between global and local optimization involves a trade-off between optimality guarantees and computational cost. Two open-source frameworks for ML-based inverse planning were compared: OptiCL (global mixed-integer optimization via constraint learning) and pyanno4rt (local nonlinear optimization via end-to-end differentiation). Logistic regression, linear support vector machine, and feed-forward neural network NTCP models for grade 2+ xerostomia and grade 2+ radiation pneumonitis were embedded. Plan optimization was performed for eight head-and-neck (HN) photon cases and seven lung proton cases. The plans were compared by target coverage, OAR dose metrics, spatial dose agreement, post-hoc predicted NTCP, and runtime. A projection-based gradient approximation was introduced to embed decision trees. In addition to that, warm-starting, constraint strengthening, and pruning were investigated as hybrid strategies for combining local and global optimization. Comparing OptiCL and pyanno4rt across the HN and lung treatment plans revealed broadly consistent dose distributions. Mean differences (OptiCL}$-$pyanno4rt [95% CI]) were small: for HN cases, -0.16 Gy [-0.37, 0.06] (parotid) and -0.00 Gy [-0.01, 0.00] (PTV); for lung cases, -0.52 Gy [-1.10, 0.06] (total lung) and -0.04 Gy [-0.07, -0.01] (PTV). Mean NTCP differences amounted to -0.08 p.p. [-0.49, 0.33] (HN) and -1.73 p.p. [-2.68, -0.77] (lung). OptiCL tended toward lower OAR doses and predicted NTCP, but required higher wall-clock runtime. Hybridization of the decision tree-based HN plan eliminated 80% of binary decision variables without compromising plan quality.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- The authors compared two open-source frameworks for ML-based inverse planning: OptiCL (global mixed-integer optimization via constraint learning) and pyanno4rt (local nonlinear optimization via end-to-end differentiation).
- Across eight head-and-neck (HN) photon cases and seven lung proton cases, mean differences in dose were small: for HN cases, -0.16 Gy [-0.37, 0.06] (parotid) and -0.00 Gy [-0.01, 0.00] (PTV); for lung cases, -0.52 Gy [-1.10, 0.06] (total lung) and -0.04 Gy [-0.07, -0.01] (PTV). Mean NTCP differences were -0.08 p.p. [-0.49, 0.33] (HN) and -1.73 p.p. [-2.68, -0.77] (lung).
- OptiCL tended toward lower OAR doses and predicted NTCP but required higher wall-clock runtime. Hybridization of the decision tree-based HN plan eliminated 80% of binary decision variables without compromising plan quality.
Readers' thoughts
No reader thoughts yet.
Related papers
- From Linear-quadratic to Machine Learning in Radiobiological Modeling for Radiotherapy Planning: Resolving the Complexity-Utility Paradox with Hybrid Physics-informed Neural Networks.Journal of medical physics · 2026
- Reference‐Free large language model agents for physician‐guided radiotherapy treatment planningMedical Physics · 2026
- Dosimetric parameter-based machine learning to predict radiation pneumonitis following breast radiotherapy.Physics in medicine and biology · 2026
- Uncertainty-Aware Multiscale Treatment Response Forecasting in Advanced Non-Small Cell Lung Cancer Using Residual-Variance Conformal Prediction.medRxiv : the preprint server for health sciences · 2026
- Towards consensus on practical probabilistic evaluation metrics for clinical decision making in radiotherapyarXiv · 2026
- A Large Language Model Framework for Seed Implant Brachytherapy: Adaptive Weight Optimization via Retrieval-Augmented Generation.Annals of the New York Academy of Sciences · 2026