Key points
From the paper's conclusion- We fully characterize 1787 traps and use this information to estimate their contribution to the single-electron background in SENSEI.
Abstract
Skipper Charge-Coupled Devices (Skipper-CCDs) are detectors with sub-electron resolution, allowing them to play a critical role in rare-event searches. A major challenge in experiments using these detectors is understanding and mitigating low-energy backgrounds which impact the single-electron rate. One potential component of the single-electron rate could arise from single-electron charge traps caused by lattice defects. In this work we use a new in-situ technique for generating uniform charge known as ``pixel-pumping'' across the CCD to study single-electron traps in a SENSEI sensor placed underground in the MINOS cavern at Fermilab, which enables sensitivity to long-lived traps with emission times $>10^3$ seconds, a regime that was previously not accessible. We fully characterize 1787 traps and use this information to estimate their contribution to the single-electron background in SENSEI. Through simulation, we find the characterized population of traps does not significantly impact the single-electron rate. We further identify the energies and cross-sections for traps to which this analysis is sensitive, and compare this with the values that could impact the single-electron rate. This analysis probes a large fraction of this region. However, we also see that a sufficiently numerous hidden population could contribute significantly to the single-electron rate, and new measurement techniques will have to be devised in order to fully rule out this population.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Characterization of spurious-electron signals in the double-phase argon TPC of the DarkSide-50 experiment.The European physical journal. C, Particles and fields · 2026
- Self-Referenced Diagnosis of SPAD Dark-Count-Rate Switching for Quantum Communication ReceiversarXiv · 2026
- Long-term scintillation light performance, calibrations, and triggering efficiency in the MicroBooNE detectorJournal of Instrumentation · 2026
- Low Frequency Noise Identification for the SuperCDMS Experiment using Convolutional Neural NetworksarXiv · 2026
- Uncooled Photon‐Counting Detectors: From PMTs to CMOS‐Integrated and Emerging SPAD TechnologiesLaser & Photonics Reviews · 2026
- Development of millikelvin scintillation photodetectors with CUPIDarXiv · 2026