A low-cost compact muon detector for millikelvin operation
Tengiz Ibrayev, Danish Khan, Alex Herscovics, Komal Kataruka, Matilda Lawton, Sandhya Sharma, Steven Waddy, Laura Manenti
Key points
From the paper's conclusion- We present a low-cost, compact muon detector consisting of two plastic scintillator modules, each read out by a silicon photomultiplier (SiPM), operated in coincidence.
Abstract
Ionizing radiation produces correlated errors in superconducting qubits, posing some challenges to quantum error correction. In addition, it causes background events in other superconducting cryogenic devices, such as kinetic inductance detectors and superconducting nanowire single-photon detectors. Cosmic muons are a component of this background that can only be partly shielded against at ground level, but can be tagged by an independent detector inside the cryostat, so that the affected data can be vetoed, or the muon tags incorporated into error correction. We present a low-cost, compact muon detector consisting of two plastic scintillator modules, each read out by a silicon photomultiplier (SiPM), operated in coincidence. We characterize the SiPMs from room temperature down to 10 mK, including the breakdown and upper-limit voltages that define the operating bias range. Operated as a muon counter, the detector measures a coincidence rate that, as expected, is independent of temperature within uncertainties and agrees with analytical and Monte Carlo predictions. Below approximately 8 K, each muon event produces two pulses, one narrow and one broad, an effect that, to our knowledge, has not been reported before. Coincidences with an independent muon detector outside the cryostat confirm that muons are still counted reliably in this regime. By studying the appearance of double pulses as a function of temperature and magnetic field up to 4.5 T, we find a behavior consistent with the phase diagram of a type-II superconductor. This links the double pulses to a superconducting material in the SiPM, likely an adhesion layer or diffusion barrier introduced during manufacturing. The mechanism by which the superconducting state produces the second pulse is not yet understood.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Characterization of Radiation-Induced Errors in Superconducting Qubits Protected with Various Gap-Engineering StrategiesPRX Quantum · 2026
- The CosmicWatch Desktop Muon Detector (v3X): Prototype Design and Adaptation for SpaceflightarXiv · 2026
- MuSTRNG: A Muon-Based Synchronizable True Random Number Generation SystemarXiv · 2026
- Radiation Response of NbN Superconducting Nanowire Single-Photon Detectors Under $^{210}$Po Alpha-Particle IrradiationarXiv · 2026
- Radiation damage and recovery of SiPMs exposed to low-momentum muon beams for innovative scintillation-based muon beam monitorsarXiv · 2026
- Corrective-Pulse-Assisted Low-Ic SFQ Ring Oscillator for Cryogenic Microwave Burst GenerationSuperconductor Science and Technology · 2026