arXivPreprintOpen accessphysics.chem-ph

The Reference Set Is Not the Answer Set: GEOM-DRUGS Is Missing Low-Energy Conformers on Its Own Energy Surface

Alvand Vahediahmar, Aaron Zweig, Mingxuan Zhang, Elham Azizi

Computational

Key points

From the paper's conclusion
  • Together, these results show that GEOM-DRUGS precision is sensitive not only to generator quality but also to incomplete reference support.

Abstract

Machine-learned conformer generators are scored on GEOM-DRUGS by proximity to a reference ensemble that standard benchmark metrics implicitly treat as ground truth. We test whether that finite set is complete on the GFN2-xTB surface used to construct it. Across five public generators, settled, low-energy structures remain outside the $0.75$\,\AA{} reference radius after removing reflections, incorrect stereochemistry, and post-relaxation connectivity changes ($2.3$--$7.0\%$ of submitted conformers, depending on architecture). In a targeted DFT audit, $107$ of $113$ chemically screened novel/reference pairs remain outside that radius after full $\omega$B97X-D3BJ re-optimization. A threshold-free complementary test needs no radius and no energy window at all: on $15.0\%$ $[8.0, 22.0]$ of molecules some generator has already found a chemically intact structure lying below the \emph{entire} released ensemble. A complementary CREST search reproduces the minimum released in $65$ of $69$ molecules, and in $11$ of them it reaches more than $0.5$\,kcal/mol below the complete released ensemble. Augmenting the references with conformers proposed by held-out architectures raises absolute coverage-precision for every generator tested, by $1.48$--$2.99$ points. Together, these results show that GEOM-DRUGS precision is sensitive not only to generator quality but also to incomplete reference support.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers