PPG-Bench: A Unified Benchmark for PPG Foundation Models
Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
Key points
From the paper's conclusion- We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification.
Abstract
Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence Enabled Diagnostics Using Photoplethysmography (PPG): Beyond SpO2 and Heart Rate.Life (Basel, Switzerland) · 2026
- Unlocking the Specialization Capability of PPG Foundation Models for Wearable Signals through Structured Pruning and Adaptive Fine-TuningarXiv · 2026
- A Scoping Review of Deep Learning Methods for Photoplethysmography Data.Health data science · 2026
- A Physiology- and Measurement-Informed Framework for Evaluating PPG Features in Cuffless Blood Pressure Estimation.Physiological measurement · 2026
- A narrative review of methods for estimating blood pressure waveforms from photoplethysmography.Journal of clinical monitoring and computing · 2026
- PPG-IDR: Leveraging User Identity for Robust Cross-user PPG Sensing via Disentangled RepresentationsProceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · 2026