Cardiac segmentation for ventricular tachycardia radioablation and radiotherapy patients with cardiac implants.
Nicholas Summerfield, Dustin Jacqmin, Chase Ruff, Andrew M Baschnagel, Adam Burr, Michael Bassetti, Ryan Kipp, Matthew Kalscheur,
Key points
From the paper's conclusion- We apply a DL model for RT patients with ICDs or undergoing VT-SBRT, enabling segmentation and CS-level dose analysis.
Abstract
Deep-learning (DL) segmentation enables cardiac substructure (CS) delineation for advanced cardiac-sparing radiation therapy (RT). Patients presenting for RT may have implantable devices (cardioverter-defibrillators (ICDs)) and metal artifacts. Stereotactic body RT (SBRT) is used to treat ventricular tachycardia (VT), a population frequently with ICDs. We apply a DL model for RT patients with ICDs or undergoing VT-SBRT, enabling segmentation and CS-level dose analysis. CT simulation (CT-SIM) of 19 patients with ICDs and received VT-SBRT were evaluated. A validated segmentation model was retrained using a highly-curated CT-SIM cohort, supplemented with ICD images for training and validation, with a hold-out ICD test set (n=10), to predict 20 CS. Additional CT-SIM datasets included cancer-RT patients with (n=9) and without (n=10) ICDs to evaluate generalizability. The retrained ICD-supplemented model was compared against a non-ICD model using Dice similarity coefficient (DSC), 95% Hausdorff distance (HD95), and Wilcoxon signed-rank test (p<0.05). Dosimetric evaluation was performed for VT-SBRT CS. For VT-SBRT, the ICD-supplemented model achieved average DSC/HD95 of 0.71(0.19)/10.7(22.5)mm respectively, outperforming (p<0.05) the non-ICD model. On CT-SIM with ICDs, average DSC/HD95 were 0.70(0.22)/7.9(5.1)mm respectively, outperforming (p<0.05) the non-ICD model. On CT-SIM without ICDs, the average DSC was 0.74(0.17) (Non-ICD, DSC, 0.75(0.16), p<0.05) and average HD95 was 5.5(3.1)mm (Non-ICD, HD95, 5.3(2.8mm)). For VT-SBRT, CS dose depended on target location, with higher relative dose delivered to the ventricles, tricuspid valve, atrioventricular node, and left coronary arteries than other CS. ICD-supplemented training improved CS segmentation despite metal artifacts without meaningfully degrading non-ICD performance, supporting segmentation and CS-level dosimetry in ICD populations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- VentrEX: An Anatomically Guided Deep Learning Pipeline for Ventricular Segmentation in Cine Cardiac MRI.Journal of imaging · 2026
- Quantifying the Impact of Upright Patient Positioning on Cardiac Substructures Using Deep Learning.ArXiv · 2026
- Preliminary LGE- CMR defined scar consolidation after stereotactic cardiac radiotherapy for refractory ventricular tachycardia: a retrospective pilot analysisEuropean Heart Journal · 2026
- Multicenter Evaluation of a Deep Learning Model for Automatic Contouring of Cardiac Substructures in Adults.Practical radiation oncology · 2026
- Artifact-resilient deep learning segmentation for enhanced structural and functional cardiac analysisScientific Reports · 2026
- Cardiac CT foundation model for whole-heart segmentation: integrating human-in-the-loop and self-supervised learningEuropean Heart Journal · 2026