Magnonic cavity-enhanced quantum magnetometry with nitrogen-vacancy centre ensembles
Nikhil Kumar
Key points
From the paper's conclusion- Nitrogen-vacancy (NV) centre ensembles are leading room-temperature magnetometers, but their sensitivity is usually extracted from a single resonance and relies on external microwave and bias-field hardware.
Abstract
Nitrogen-vacancy (NV) centre ensembles are leading room-temperature magnetometers, but their sensitivity is usually extracted from a single resonance and relies on external microwave and bias-field hardware. This work proposes a chip-scale NV magnetometer built around a one-dimensional YIG/CoFeB magnonic crystal, in which a single structural defect forms a passive magnonic cavity and integrated permanent magnets supply the bias field. Micromagnetic simulations show a defect-localised spin-wave mode at 2.910 GHz inside the 2.5-3.0 GHz magnonic band gap, 40 MHz from the NV zero-field splitting, with a band structure that matches an independent plane-wave calculation. A Tavis-Cummings/Lindblad model in which the microwave reaches the NV ensemble through this mode predicts a hyperfine-resolved optically detected magnetic resonance spectrum that is strong only within the mode linewidth, and a dispersive homodyne response with one steep edge per $^{14}$N hyperfine line. The master-equation solutions agree with the closed-form homodyne steady state ($R^2 > 0.9999$) and with an approximate analytic ODMR theory (peak positions within 0.012 MHz). For a critically coupled readout with room-temperature electronics, combining the three edges gives a projected sensitivity of 93 pT/$\sqrt{\rm Hz}$, a $\sqrt{3}$-fold gain over the best single edge. Mapping the sensitivity against the NV-magnon coupling reveals an optimum near $g_{\rm ens}/2\pi \approx 0.2$-$0.4$ MHz, where it reaches 72 pT/$\sqrt{\rm Hz}$ for a 0.64 MHz spin linewidth and 19 pT/$\sqrt{\rm Hz}$ for 0.17 MHz, with thermal limits of 6.6 and 1.7 pT/$\sqrt{\rm Hz}$. The antenna-mode coupling, the NV-magnon coupling and the spin linewidth are therefore the main design levers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of an ultrahigh-vacuum-compatible cryogen-free scanning nitrogen-vacancy magnetometer.The Review of scientific instruments · 2026
- Broadband AC magnetic field sensing via continuous wave optically detected magnetic resonance with NV centers in diamondJapanese Journal of Applied Physics · 2026
- Infrared-absorption magnetometry in a diamond nanocavity: demonstration and limits at the nanoscalearXiv · 2026
- Axis-selective AC magnetic-field imaging in the tens-of-megahertz regime using RF-dressed continuous-wave scanning NV magnetometryarXiv · 2026
- Machine Learning-Based Characterisation of the Non-Markovian Dynamics of a Nitrogen-Vacancy CentrearXiv · 2026
- Continuous-wave AC magnetometry up to hundreds of megahertz using nitrogen-vacancy centers under a strong transverse magnetic fieldarXiv · 2026