Image-Based Breast Implant Detection for Mammography Dataset Curation and Near-Real-Time Deployment: Comparing Foundation Models and Task-Specific Convolutional Models
Vasisht Ishwar, Hari Trivedi, Young Seok Jeon, Beatrice Brown-Mulry, Frank Li, Rohan Satya Isaac, Mohammadreza Chavoshi, Judy Wawira Gichoya
Key points
From the paper's conclusion- Purpose: To evaluate the performance-feasibility tradeoffs of foundation models (FMs) and task-specific convolutional neural networks (CNNs) trained from scratch for breast implant classification in 2D mammography, with emphasis on suitability for near real-time clinical deployment.
Abstract
Purpose: To evaluate the performance-feasibility tradeoffs of foundation models (FMs) and task-specific convolutional neural networks (CNNs) trained from scratch for breast implant classification in 2D mammography, with emphasis on suitability for near real-time clinical deployment. Methods: We evaluated four models: two FMs (RAD-DINO and MammoCLIP) and two CNNs trained from scratch for implant prediction (ResNet18 and our lightweight ResNetLite). Using the Emory Breast Imaging Dataset, 5,000 unilateral screening mammograms were used for training/validation and 1,000 manually reviewed unilateral images were held out for testing. For the FMs, global image embeddings from the pretrained encoder were classified using a support vector machine (SVM). The CNNs were trained end-to-end on 2D mammograms, with ResNetLite optimized via grid search over depth and width to balance accuracy and efficiency. Performance was evaluated using AUROC, sensitivity, specificity, accuracy, embedding visualization, and inference-latency. Results: All models demonstrated strong performance on held-out test data (n = 1,000). MammoCLIP achieved the highest AUROC (0.999) with the quickest training time of 493 seconds. RAD-DINO achieved the highest sensitivity (0.980; accuracy 0.989) but had the slowest inference and training times. ResNet18 and MammoCLIP achieved comparable accuracy (0.985). ResNetLite showed no statistically significant difference from ResNet18 (AUROC 0.993; accuracy 0.976) despite using only 1.4% of ResNet18's parameters, and had the fastest inference time. Conclusion: FMs and task-specific CNN models reliably detect breast implants on 2D mammography. Model selection is best guided by deployment context: MammoCLIP for GPU-equipped hospital settings requiring scalable integration, and lightweight CNNs such as ResNetLite for resource-constrained or edge deployments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimizing the Mammography AI Pipeline: From Data Filtering to Vision-Language ModelsInformatics · 2026
- LBNet: an optimized lightweight CNN for mammographic breast cancer classification with XAI-based interpretabilityScientific Reports · 2025
- Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?arXiv · 2026
- When multi-institutional dataset aggregation masks shortcut-like behavior in Foundation Models for medical imaging.Medical image analysis · 2026
- RV-Net: Lesion-Mask-Supervised Two-View Mammography Classification at the Breast Level with Patient-Disjoint Evaluation on CBIS-DDSM and CMMDBioengineering · 2026
- A hybrid vision transformer–CNN ensemble with radiomics fusion for robust cross-dataset breast cancer detection in mammographyDiscover Artificial Intelligence · 2026