End-to-End Autonomous Recursive Arborescence Deformable Flow and Non-Linear Hemodynamics for Patient-Specific Coronary Centerline Extraction
Zeyu Jia, Xin Ming
Key points
From the paper's conclusion- We formulate an end-to-end framework decoupling continuous geometric arborescence generation from non-linear hemodynamics.
Abstract
Extracting patient-specific vascular trees from volumetric medical images is fundamental to computational angiography and non-invasive hemodynamic assessment. Conventional voxel segmentation models often sever delicate bifurcations, while heuristic Euclidean Minimum Spanning Trees introduce non-anatomical shortcuts. Moreover, linear Poiseuille flow neglects quadratic kinetic dissipation across arterial narrowings, underestimating ischemia. We formulate an end-to-end framework decoupling continuous geometric arborescence generation from non-linear hemodynamics. First, an autonomous 3D Ostium Landmark Localization Head with dual-sinus query channels and spherical-gated refinement eliminates centerline seeding dependency, achieving cohort mean localization error of 7.63 mm (7.43 mm LCA, 7.83 mm RCA; 71.4% <= 8.0 mm) from raw contrast context. Second, a Spatially-Grounded Deformable Step Flow Architecture queries continuous 3D feature pyramids via trilinear sampling, sequentially generating trajectories with anchor boundary enforcement (X(0) = P_start). Third, a Top-Down Recursive Arborescence State Machine detects bifurcation peaks via Tree-NMS and parameterizes predecessor parent pointers (p_k < k), guaranteeing single connected acyclic tree topology (beta_0 = 1, beta_1 = 0) with differentiable step termination. Fourth, an iterative Picard non-linear Kirchhoff solver with Young-Tsai / Gould quadratic dissipation enforces machine-precision mass conservation (residual 5.82e-11 mL/s). Across 14 development patients under standardized in-silico stenosis stress testing (Q_0 = 4.0 mL/s), linear Poiseuille flow misclassifies 75% diameter lesions as non-ischemic (FFR > 0.80) in 14/14 cases, whereas our non-linear solver captures functional ischemia (FFR = 0.5864, lesion disparity 32.89 mmHg, p = 6.10e-5) with 3.66x collateral shunting. Test set firewall isolation was maintained.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic ViewsarXiv · 2026
- FlowPredictor-Corrector: A Hemodynamics-Guided Two-Step Deep Learning Framework for Vascular Flow Prediction.IEEE journal of biomedical and health informatics · 2026
- Beyond Segmentation: Enriching ImageCAS with Coronary Ostia Landmarks, Rooted Centerline Graphs, and Open-Weight Localization ModelsarXiv · 2026
- CARS: a centerline-anchored attention surrogate for coronary blood flow on skeleton-generated lumen geometriesarXiv · 2026
- Cerebrovascular flow field reconstruction method based on residual network of physical information.Frontiers in bioengineering and biotechnology · 2026
- Physics-Informed Implicit Neural Networks for 3D Coronary Artery Reconstruction.Journal of imaging informatics in medicine · 2026