Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc

Myopic Shift in Patients During Hyperbaric Oxygen Treatment: A Systematic Review.

Knut Evanger, Guro Vaagbø, Olav Henrik Haugen, Bernd Müller

Department of Clinical Medicine, University of Bergen, Bergen, Norway. · Hyperbaric Medicine Unit, Department of Occupational Medicine, Haukeland University Hospital, Bergen, Norway.

Review

Key points

From the paper's conclusion
  • Of 153 reports identified, eight studies with 263 patients were included. Treatment durations covered 18-21, 30, and 40 treatments in either monoplace or multiplace chambers using hoods or masks. For the mean values of myopic shift and the incidence of a myopic shift ≥ 0.5 D, a range was seen from the lowest values after 20 treatments in multiplace chambers using a mask (0.4 D and 53%, respectively), to the highest values after 40 treatments using hoods (1.6 D and 100%, respectively). For monoplace treatment, the corresponding numbers were 0.6 D and 70% after 18 treatments, and 0.95 D and 91% after 30 treatments.

Abstract

INTRODUCTION: CReversible myopic shift (MS) is a common side effect of hyperbaric oxygen treatment (HBO₂) resulting from refractive changes in the lens. Single studies indicate that the myopic shift increases with longer duration of HBO₂ and may differ between hyperbaric chamber types and oxygen breathing systems. This review aims to improve knowledge on the frequency and magnitude of myopic shift after standard-length HBO₂. METHODS: A systematic search for original studies of myopic shift after HBO₂ was conducted in medical databases. Included were published full-text articles in English with specified details on oxygen administration, pressure, number of treatments, and use of conventional techniques to measure refraction. Studies with exposure other than HBO₂, patients with artificial lenses, and single-case reports were excluded. RESULTS: Of 153 reports identified, eight studies with 263 patients were included. Treatment durations covered 18-21, 30, and 40 treatments in either monoplace or multiplace chambers using hoods or masks. For the mean values of myopic shift and the incidence of a myopic shift ≥ 0.5 D, a range was seen from the lowest values after 20 treatments in multiplace chambers using a mask (0.4 D and 53%, respectively), to the highest values after 40 treatments using hoods (1.6 D and 100%, respectively). For monoplace treatment, the corresponding numbers were 0.6 D and 70% after 18 treatments, and 0.95 D and 91% after 30 treatments. DISCUSSION: This review indicates that both the magnitude and incidence of myopic shift increase with the number of HBO₂ sessions and in the order multiplace-mask < monoplace < multiplace-hood.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Myopic Shift in Patients During Hyperbaric Oxygen Treatment: A Systematic Review — Science Skim