From the paper's conclusion- Across three tissue detection methods, false positives followed the fraction of such clear-space tissue in the pool, a statistic that needs no labels or training (0.103, 0.016 and 0.009).
Abstract
One-class artifact detectors for whole-slide images learn normal tissue from a clean training pool and flag departures from it. The pool is built by a preprocessing pipeline whose tissue-detection step is usually treated as neutral. We tested whether it is. On 16 annotated TCGA slides, we rebuilt the clean pool of a diffusion-based detector with different tissue detection methods and compared the resulting models in a four-fold cross-validation. Per-slide saturation-Otsu detection excluded normal tissue, chiefly tissue with large clear spaces such as adipose tissue and alveolar parenchyma, and on slides with thick marker ink kept the ink while excluding ordinary tissue. Replacing it with entropy-based detection reduced the false-positive fraction on held-out clean slides from 0.102 to 0.016, in every fold and with a second training seed, without loss of sensitivity; the gain came from the composition of the pool, not its size. Across three tissue detection methods, false positives followed the fraction of such clear-space tissue in the pool, a statistic that needs no labels or training (0.103, 0.016 and 0.009). The effect did not carry over at the same size to a nearest-neighbour detector on foundation-model features. On an external cohort, the curated pool lowered clean-control false positives by about 20%, far less than within TCGA, and the remaining cross-center loss was not explained by stain differences. For one-class quality control, tissue detection decides what the model learns as normal and should be chosen and reported accordingly.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliable Benchmarking of Artifact Detection in Computational Pathology: A Reproducibility and Uncertainty AnalysisarXiv · 2026
- SCOUT: Risk-Guided Foundation-Model Escalation for Robust Tissue Detection in Whole-Slide ImagesarXiv · 2026
- The APL Doesn't Fall Far From The Tree: Unsupervised Artefact Prototype Learning in HistopathologyarXiv · 2026
- Benchmarking and Improvement of Artifact Segmentation Methods in H&E-Stained Whole Slide ImagingarXiv · 2026
- BigpictureQC: multi-stain, multi-species artifact segmentation for whole-slide quality controlBMC Medicine · 2026
- Seeing Beyond the Lesion: Disease Recognition from Reactive CNS TissuearXiv · 2026