Multi-Site Real-World Performance of Commercial AI for Pulmonary and Incidental Pulmonary Embolism Detection
Aawez Mansuri, Mohammadreza Chavoshi, Theodorus Dapamede, Wasif Bala, Beatrice Brown-Mulry, Rohan Isaac, Bardia Khosravi, Hanzhou Li,
Key points
From the paper's conclusion- We retrospectively evaluated two FDA-cleared AI algorithms from a single commercial platform (Aidoc Medical BriefCase), one for PE triage on dedicated CT pulmonary angiography (CTPA; n = 30,678) and one for incidental PE (iPE) detection on routine contrast-enhanced CTs (n = 37,191), across a 17-facility academic health system.
Abstract
Pulmonary embolism (PE) is a leading cause of cardiovascular mortality, yet the real-world performance of FDA-cleared AI detection models remains incompletely characterized. We retrospectively evaluated two FDA-cleared AI algorithms from a single commercial platform (Aidoc Medical BriefCase), one for PE triage on dedicated CT pulmonary angiography (CTPA; n = 30,678) and one for incidental PE (iPE) detection on routine contrast-enhanced CTs (n = 37,191), across a 17-facility academic health system. Reference-standard labels were extracted from radiology reports using a validated LLM pipeline (97% accuracy, kappa = 0.94). The PE model achieved 86.8% sensitivity and 99.1% specificity, with sensitivity declining from 99.3% for saddle emboli to 72.9% for subsegmental PE, and from 89.7% for acute to 65.3% for non-acute PE. The iPE model achieved 73.5% sensitivity and 99.8% specificity. Both models demonstrated lower sensitivity than FDA-clearance benchmarks while exceeding cleared specificity, with diminishing performance for peripheral and non-acute emboli mirroring known human reader limitations and underscoring the need for standardized post-market surveillance of AI-enabled medical devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Silent Drift and Site-level Variance in Clinical AI: Real-world performance and subgroup analysis for post-market monitoring of an FDA-cleared artificial intelligence (AI) triage tool for high-risk use case of pulmonary embolismmedRxiv · 2026
- Clinical Implementation of AI for Pulmonary Embolism Detection in over 30 000 CT Pulmonary Angiography ExaminationsRadiology Artificial Intelligence · 2026
- Incidental Pulmonary Embolism Detection on Routine Contrast-Enhanced CT before and after Deployment of a Commercial AI Tool: A Real-World Evaluation.The British journal of radiology · 2026
- Evaluation of artificial intelligence for pulmonary embolism detection on CTPA: A single-center retrospective study comparing AI, radiologists, and AI-assisted interpretation.Medicine · 2026
- Diagnoses of pulmonary embolism from non-contrast 4DCT using image processing-derived quantitative perfusion scoresnpj Biomedical Innovations. · 2026
- External validation of a top-ranked model from the RSNA pulmonary embolism detection challenge: assessment of generalizability.Scientific reports · 2026