Foundation-model-based multi-label phenotyping of combined hyperkinetic movement disorders
Laura Cif, Zohra Souei, Diane Demailly, Mayte Castro-Jimenez, Juan Dario Ortigoza-Escobar, Muhammad Mushhood Ur Rehman, Morgan Dornadic, Sophie Huby,
Key points
From the paper's conclusion- We combined two foundation models into one frozen backbone: Segment Anything Model 3 (SAM 3) for dense, per-frame markerless segmentation summarized into geometric, contour and grid kinematic signals, and TabICLv2, a tabular foundation model, for in-context multi-label classification of eight hyperkinetic MD phenomenologies.
Abstract
Movement disorders (MDs) frequently co-occur, yet phenomenological and severity assessment shows substantial inter-rater variability. Markerless video could improve reproducibility, but prior work is largely single-symptom, depends on standardized acquisition, and lacks validation and transfer across ages and sites. We combined two foundation models into one frozen backbone: Segment Anything Model 3 (SAM 3) for dense, per-frame markerless segmentation summarized into geometric, contour and grid kinematic signals, and TabICLv2, a tabular foundation model, for in-context multi-label classification of eight hyperkinetic MD phenomenologies. Trained on standardized recordings of 21 adults and 4 controls, it transferred unchanged to two independent datasets, pediatric (n=12) and tremor-dominant adult (n=20), assessed with the CODY-SAMP scale; only the patient-level decision step was recalibrated per site. Under clinician consensus labels, false positives fell to zero in both datasets. Dystonia recovered perfectly (7/7 pediatric; 15/15 adult held-out), chorea fully in children (3/3), and tremor was recovered in adults (11/15) once a tremor-rich cohort made it evaluable, through recalibration alone. Per-region effect-size analysis gave clinically coherent, phenomenology-specific signals and identified myoclonus as the principal failure. Against YOLOv8 sparse keypoints, the dense representation matched under clinician permissive labels (Jaccard 0.63 vs 0.63) and was markedly more robust under clinician-label consensus (0.93 vs 0.76). This frozen foundation-model backbone with light per-site calibration yields transferable, interpretable, conservative multi-label phenotyping of co-occurring hyperkinetic MDs across ages and from standardized to routine video, adding robustness on high-confidence, clinician-agreed labels. Prospective multi-centre validation is required before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Simultaneous hyperkinetic movement disorders phenotyping: a cross-cohort pediatric transfer study using routine videos, markerless pose estimation and a tabular foundation model.Frontiers in neurology · 2026
- Bridge-Disease Curriculum Transfer Enables Smartphone-Based Balance Assessment in Rare Neurologic Disorders.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
- Abnormal head movements in neurological conditions: a knowledge-based dataset with application to cervical dystonia.Frontiers in digital health · 2026
- Deep learning models detect neuromuscular disease and quantify functional impairment from video-derived biomechanics data.bioRxiv : the preprint server for biology · 2026
- Machine Learning Applied to Montreal Cognitive Assessment Subdomains for Differential Diagnosis of Neurodegenerative Movement Disorders: Classification Limits and Deterministic Score Reconstruction.Bioengineering (Basel, Switzerland) · 2026
- Markerless Motion Capture Reveals Movement Abnormalities in Isolated REM Sleep Behavior DisordermedRxiv · 2026