arXivPreprintOpen accessphysics.flu-dyn

Comment on "Note on the start-up of Couette flow for viscoelastic fluids" [Phys. Fluids 35, 113108 (2023)]

Ivan C. Christov

Key points

From the paper's conclusion
  • Fluids 35, 113108 (2023)] are incompatible with a nonzero retardation time, so that the problem solved is not impulsive start-up, but, as I prove exactly, the start-up of a plate ramped as $1 - \mathrm{e}^{-t/λ_2}$ on the retardation timescale $λ_2$ (a material parameter, not a setting in a rheometer).

Abstract

I show that the initial conditions imposed by Balan [Phys. Fluids 35, 113108 (2023)] are incompatible with a nonzero retardation time, so that the problem solved is not impulsive start-up, but, as I prove exactly, the start-up of a plate ramped as $1 - \mathrm{e}^{-t/λ_2}$ on the retardation timescale $λ_2$ (a material parameter, not a setting in a rheometer). Values digitized from that paper's viscoelastic figures fall on the ramped-plate solution, not on Tanner's start-up solution. The large negative wall normal stress reported for the corotational model is a grid-dependent artifact due to the same error in the initial data. An open-source code repository provides annotated notebooks reproducing every figure and number in this Comment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.