Pixel-wise Exposure for Highly Robust In-Vehicle Remote-PPG
Jieying Wang, Xinqi Cai, Caifeng Shan, Wenjin Wang
Key points
From the paper's conclusion- We validate the proposed PixExpo framework using our newly introduced MEX-Drive dataset, comprising 48 participants under real-world driving conditions.
Abstract
Remote photoplethysmography (rPPG) offers a promising non-contact solution for heart rate monitoring, yet its real-world robustness is fundamentally limited by an inherent hardware limitation: existing camera exposure control paradigms, whether fixed or auto-exposure, impose a uniform exposure time across all pixels within a frame. In high-dynamic-range scenes such as automotive cabins with strong directional sunlight, this spatially invariant exposure constraint inevitably leads to localized facial overexposure or underexposure, irreversibly corrupting the subtle pulsatile signals essential for rPPG at the point of capture, a physical degradation that no downstream algorithm can recover. To overcome this bottleneck, we propose PixExpo (Pixel-wise Exposure), a "temporal-for-spatial" framework that sequentially captures frames under a predefined cyclic exposure schedule and performs non-iterative pixel-wise fusion. At each pixel location, PixExpo selects the observation closest to an rPPG-motivated target intensity. This criterion seeks to reduce local saturation and severe underexposure rather than optimize perceptual appearance. PixExpo requires no sensor modification but assumes programmable frame-level exposure control. We validate the proposed PixExpo framework using our newly introduced MEX-Drive dataset, comprising 48 participants under real-world driving conditions. Experimental results demonstrate that PixExpo outperforms manufacture-default auto-exposure methods, reducing the mean absolute error (MAE) by 7.21 bpm (from 13.94 to 6.73 bpm) and increasing the success rate by 37.29 percentage points (from 25.95% to 63.24%) across challenging driving scenarios.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MS-rPPG: Multi-spectral State Space Model for Remote Photoplethysmography in Driver Monitoring SystemsarXiv · 2026
- The reliability of remote photoplethysmography under low illumination and elevated heart ratesnpj Digital Medicine · 2025
- Progressive hierarchical attention and frequency-domain decoupled physiological loss for unsupervised remote photoplethysmography.Physiological measurement · 2026
- Frequency-Preserving Readout Design and Error Characterization for CWT-Based rPPG Heart-Rate Estimation.Sensors (Basel, Switzerland) · 2026
- Signal quality-guided adaptive denoising for robust remote photoplethysmography.Biomedical engineering letters · 2026
- Non-Contact Photoplethysmography for In-Vehicle Health Monitoring With Seamlessly Integrated Photodetector Array and Hardware-Accelerated AI.Small (Weinheim an der Bergstrasse, Germany) · 2026