Single-shot coherent process tomography and mid-infrared polarimetry with undetected photons
Marthe Zeja, Wen-Zhe Yan, Zhibo Hou, Sven Ramelow
Key points
From the paper's conclusion- We show that a folded nonlinear interferometer with a diagonally pumped crossed-crystal source performs coherent process tomography of the undetected beam in a single spectrometer frame: it reconstructs all seven parameters of the beam's round-trip Jones matrix, the coherent part of the channel.
Abstract
Measurements with undetected photons infer properties of a probe beam that is never detected, transferring mid-infrared information onto silicon-friendly wavelengths. Tomography in this paradigm has so far relied on switched settings or scanned phases, referenced across a drift-sensitive campaign; no protocol reads all Jones parameters from one frame. We show that a folded nonlinear interferometer with a diagonally pumped crossed-crystal source performs coherent process tomography of the undetected beam in a single spectrometer frame: it reconstructs all seven parameters of the beam's round-trip Jones matrix, the coherent part of the channel. Birefringent group-delay walk-off, normally a calibration nuisance, acts as a frequency multiplexer: each Jones-matrix element is assigned its own carrier, a spectral fringe period paired with a detector port. Because the multiplexing exploits the down-conversion bandwidth rather than merely tolerating it, a single Fourier transform per detector trace returns all four moduli and all three relative phases across that bandwidth, i.e., the full round-trip Jones spectrum up to a global phase, with no scan or setting change (after a one-time reference frame). Simultaneity makes every relative phase immune to common-mode drift, and a dark carrier, a self-interference term that unitarity forces to vanish, provides a built-in null test. For realistic parameters of a periodically poled KTP source the scheme yields wavelength-resolved mid-infrared polarimetry across 3.5-4.2 microns (~80 spectral points per Jones element) on a silicon camera, extending to depth-resolved Jones matrices, i.e., polarization-sensitive optical coherence tomography with undetected photons. A Fisher-information analysis, the first we are aware of in undetected-photon tomography, sets the precision budget and compares delay multiplexing to sequential protocols at equal photon number.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Single-shot on-chip measurement of the modal Stokes parameters.Optics letters · 2026
- High Resolution Hyperspectral Quantum Infrared Imaging with Undetected PhotonsarXiv · 2026
- Single-shot characterization of noise-like pulses via coherent reference pulse trains.Optics letters · 2026
- Mid-IR hyperspectral imaging with undetected photonsOptica · 2026
- Attosecond delay metrology beyond the photon coherence time with spectrally resolved Hong-Ou-Mandel interferometry.Reports on progress in physics. Physical Society (Great Britain) · 2026
- Jones matrix extraction using single-shot common-path digital holographic measurement.Optics letters · 2026