Balmer Absorption Series and Broad Metal Lines in Two Luminous Little Red Dots
Bingjie Wang, Jenny E. Greene, Hanpu Liu, Nicholas Kaaz, Gabriel B. Brammer, Raphael E. Hviding, Ivo Labbé, Joel Leja,
Key points
From the paper's conclusion- We find two systematic trends along the Balmer series: the absorption centroids become more redshifted toward higher-order transitions, while the absorbed equivalent widths decline only weakly with increasing order, far less than expected from the atomic optical-depth ratios for a single attenuating screen.
Abstract
Balmer absorption is common among little red dots (LRDs), but absorbers at or redward of systemic are rare, occurring in only $\sim10-15$\% of H$α$ absorbers. In this paper, we study two such exceptional cases with deep JWST/NIRSpec spectroscopy: 15 hr of high-resolution (G395H) observations of RUBIES-EGS-49140 (z=6.68), resolving the absorption in all four transitions from H$α$ through H$δ$, and medium-resolution spectroscopy (10 hr of G235M, 2 hr of G395M) of UNCOVER-A2744-45924 (z=4.46; 1.7x magnification). Both sources are among the optically reddest and most luminous LRDs known, and both show deep, near-systemic Balmer absorption troughs. We find two systematic trends along the Balmer series: the absorption centroids become more redshifted toward higher-order transitions, while the absorbed equivalent widths decline only weakly with increasing order, far less than expected from the atomic optical-depth ratios for a single attenuating screen. Ca\,{\sc{ii}}\,K is detected in absorption in both sources, whose offset follows the H$α$ trough rather than the more redshifted higher-order Balmer lines. We further report the detection of a broad base in [Ne\,{\sc{iii}}]\,$λ$3870, along with broad [O\,{\sc{iii}}]\,$λ$4364, [O\,{\sc{iii}}]\,$\lambda5008$, and He\,{\sc{i}}\,$\lambda5877,\lambda7067$, while He\,{\sc{ii}}\,$λ$4687 remains undetected or weak. Standard AGN photoionization models cannot reproduce the observed line ratios, whereas AGNs with high gas densities provide a consistent explanation, as also indicated by the anomalously high He\,{\sc{i}}\,$\lambda7067/\lambda5877$ ratio. A possible explanation for the relative strengths of the Balmer absorption lines could be a dense, optically thick medium whose re-emission modifies their apparent absorption strengths, while the velocity progression may arise from stratification in the absorbing gas.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Balmer Absorber Strength Problem of Little Red DotsarXiv · 2026
- Multiphase Gas Structure in JWST Little Red DotsarXiv · 2026
- Evidence of violation of case B recombination in little red dotsAstronomy and Astrophysics · 2026
- Little Red Dots at an Inflection Point: Ubiquitous V-shaped Turnover Consistently Occurs at the Balmer LimitThe Astrophysical Journal · 2025
- The Missing Hard Photons of Little Red Dots: Their Incident Ionizing Spectra Resemble Massive StarsThe Astrophysical Journal · 2026
- Little Red Dots at Cosmic Noon: Spectroscopic Identification and Broad-Line PropertiesarXiv · 2026