OmniCalib: Target-Free, Task-Structured Self-Calibration for Humanoid Robots
Kaixiang Lu, Haiyu Lan, Chunxiao Qiao, You Li, Enyu Li, Yehao Lu, Jiarui Yang, Peiwen Lin,
Key points
From the paper's conclusion- Using only robot-native motion and onboard sensing, we present OmniCalib, a target-free workflow that calibrates the full upper limbs---all 14 arm joint zeros and the extrinsics of both wrist and chest cameras---as well as lower limbs and the multi-camera head rig.
Abstract
Assembly, wear, and component replacement perturb the sensor extrinsics and joint zeros encoded by a humanoid CAD model. Existing procedures calibrate one sensor pair or require external fiducials. Using only robot-native motion and onboard sensing, we present OmniCalib, a target-free workflow that calibrates the full upper limbs---all 14 arm joint zeros and the extrinsics of both wrist and chest cameras---as well as lower limbs and the multi-camera head rig. Each module matches a robot-native task to a parameter block, checks observability, and writes only supported corrections to the CAD model. Our depth ICP method recovers all 14 arm joint zeros and calibrates all RGB-D camera extrinsics without any calibration target. Relative to CAD, the estimated extrinsic corrections are 10.56 mm and 1.74 degrees for the left wrist, 6.33 mm and 1.25 degrees for the right wrist, and 9.81 mm and 0.929 degrees for the chest RGB-D camera. ICP point-to-plane residual is 2.09 mm. On the same injected offsets, ICP and ArUco recover all 14 joint zeros below the 0.1-degree encoder-resolution reference. On an AGIBOT A3 Ultra humanoid, four static double-support stances recover all 12 lower-limb joint-zero offsets injected with an RMS error of 0.063 degrees. The head module combines multi-camera visual odometry with legged odometry and dynamic compensation through the live ROS transform tree. Using only planar walking, it attains a mean SO(3) error of 1.061 degrees across three sequences. The best sequence reaches 0.775 degrees, competitive with iKalibr at 0.902 degrees from rich 6-DOF excitation. Rig-relative angles repeat within 0.140 degrees. Injection recovery and held-out tests validate each observable block.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- SyncHeC: Markerless Spatio-Temporal Hand-Eye Calibration via Differentiable Rendering and Continuous-Time Joint OptimizationarXiv · 2026
- AnchorHEC: Targetless Hand-Eye Calibration of Wrist and Fixed CamerasarXiv · 2026
- Whole-Body Elasto-Geometrical Calibration of Wheeled Humanoid Robots Using a Shared-Waist Dual-Chain ModelarXiv · 2026
- Bio-Inspired High-Precision Vision-Based Hand-Eye Calibration via an Integrated Target.Biomimetics (Basel, Switzerland) · 2026
- Visual-Inertial Odometry for Ground Robots with Dynamic Camera-IMU Extrinsic CalibrationarXiv · 2026
- Geometry-Preserving Human-to-Robot Upper-Body Motion Retargeting from Monocular VideoarXiv · 2026