SetPlanner: A Lightweight Plug-in Point-Set Planner for Frozen SAM
Dawei Yan, Yuezhe Yang, Menglan Ruan, Chunfeng Yang, Yudong Zhang
Key points
From the paper's conclusion- Formulated automatic prompting as lightweight point-set planning and isolated the point source under a frozen pathway to present SetPlanner, a 1.52M-parameter plug-in point-set planner for frozen SAM.
- SetPlanner plans complete unordered K-point sets from geometry-aware targets with a permutation-aware conditional flow, and SAM decodes eight candidates; their consensus readout yields a ground-truth-free prediction.
- SetPlanner wins all six transfer routes over a LoRA-adapted system across three endoscopic datasets, reaching 0.934 Dice on Kvasir-Instrument and recovering 96% of a 44.4-point localization gap.
Abstract
Segment Anything Models provide reusable priors, yet they require user prompts and cannot support fully automatic instrument segmentation. Automatic prompting is difficult for thin, articulated, reflective, and partly occluded tools, where several configurations can be valid. We formulate automatic prompting as lightweight point-set planning and isolate the point source under a frozen pathway. To this end, we present SetPlanner, a 1.52M-parameter plug-in point-set planner for frozen SAM. The plug-in preserves SAM's point-prompt interface and enables reuse across backbones. SetPlanner plans complete unordered K-point sets from geometry-aware targets with a permutation-aware conditional flow. SAM decodes eight candidates; their consensus readout yields a ground-truth-free prediction. Across three endoscopic datasets, SetPlanner wins all six transfer routes over a LoRA-adapted system. Under our frozen-pathway protocol, SetPlanner reaches 0.934 Dice on Kvasir-Instrument and recovers 96% of a 44.4-point localization gap, while candidate disagreement ranks low-Dice cases at AUROC 0.969.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- Formulated automatic prompting as lightweight point-set planning and isolated the point source under a frozen pathway to present SetPlanner, a 1.52M-parameter plug-in point-set planner for frozen SAM.
- SetPlanner plans complete unordered K-point sets from geometry-aware targets with a permutation-aware conditional flow, and SAM decodes eight candidates; their consensus readout yields a ground-truth-free prediction.
- SetPlanner wins all six transfer routes over a LoRA-adapted system across three endoscopic datasets, reaching 0.934 Dice on Kvasir-Instrument and recovering 96% of a 44.4-point localization gap.
Readers' thoughts
No reader thoughts yet.
Related papers
- SurgGAP: Geometry-Guided Automatic Prompting for SAM2-Based Multiclass Surgical Instrument Video SegmentationElectronics · 2026
- ProtoSAM for automated one shot medical image segmentation using foundational modelsScientific Reports · 2025
- Segment Anything In-Context via Visual DemonstrationsarXiv · 2026
- Adapting Open-Weight MLLMs to Generate Point Prompts for Electron Microscopy SegmentationarXiv · 2026
- Distillation-SAM: Knowledge Distillation-Based Auto-Prompt Embedding Learning for Surgical Image SegmentationIEEE Transactions on Medical Imaging · 2026
- Segment Anything Model 2: An Application to 2D and 3D Medical ImagesIEEE Transactions on Biomedical Engineering · 2026