Demonstrating topological identification capabilities of the NEXT experiment at low pressure
J. Waiton, H. Almazán, B. Palmeiro, G. Martínez-Lema, R. Guenette, V. Álvarez, L. Arazi, I. J. Arnquist,
Key points
From the paper's conclusion- These results demonstrate the excellent topological discrimination capabilities of the NEXT-100 detector in line with NEXT-White, which achieved a signal efficiency and background acceptance of 71.6 $\pm$ 1.5 (stat.) $\pm$ 0.3 (syst.) % and 20.6 $\pm$ 0.4 (stat.) $\pm$ 0.3 (syst.) % respectively.
Abstract
The NEXT-100 detector is a high-pressure xenon time projection chamber utilising electroluminescence amplification for sub-1% FWHM energy resolution and topological discrimination, two key attributes required to achieve the NEXT programme's overarching goal of detecting neutrinoless double beta decay ($0 νββ$). The detector has completed its first physics run at the Laboratorio Subterráneo de Canfranc (LSC), with xenon at a pressure of $\sim$4 bar. In this paper we report on the first validation of NEXT-100's topological performance and present the first topological analysis conducted at low pressure within the detector programme. A Monte Carlo study characterising the effects of pressure on track topology is presented, with qualitative agreement observed in data. We then demonstrate the topological discrimination capabilities for $0νββ$-like events from $^{208}$Tl decays using a cut-based method considered the 'baseline' in NEXT's topological programme, upon which all future analyses will improve. The analysis described applies a set of selection cuts before implementing a background discrimination algorithm that yields a reported signal efficiency for double-electron tracks and background acceptance for single-electron tracks of 75.6 $\pm$ 1.9 (stat.) $^{+3.4}_{-4.1}$ (syst.) % and 14.7 $\pm$ 0.4 (stat.) $^{+0.7}_{-0.8}$ (syst.) %. These results demonstrate the excellent topological discrimination capabilities of the NEXT-100 detector in line with NEXT-White, which achieved a signal efficiency and background acceptance of 71.6 $\pm$ 1.5 (stat.) $\pm$ 0.3 (syst.) % and 20.6 $\pm$ 0.4 (stat.) $\pm$ 0.3 (syst.) % respectively.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The NEXT-100 DetectorThe European Physical Journal C · 2026
- Evaluation of tracking plane pitch and xenon-helium gas mixtures for the NEXT experimentarXiv · 2026
- A REST-based Monte Carlo Simulation and Data Analysis Framework for the N$\nu$DEx ExperimentarXiv · 2026
- Optical imaging in dual-phase xenon time projection chambers for neutrinoless double beta decay searchesarXiv · 2026
- Simulation and Rejection of Radon Progeny Backgrounds in nEXOarXiv · 2026
- Operating a large-diameter dual-phase liquid xenon TPC in the unshielded PANCAKE facilityThe European Physical Journal C · 2026