TRACE: Two-Stage Detector-Response Estimation With Angular Cosine Expansion for Ring Artifact Correction in Photon-Counting CT
Jigang Duan, Heran Wang, Ligen Shi, Zheng Sun, Ping Yang, Xing Zhao
Key points
From the paper's conclusion- We propose TRACE, a two-stage unsupervised sinogram decomposition method for estimating and correcting these response-related errors.
Abstract
Detector response nonuniformity introduces systematic projection errors and ring artifacts in photon-counting detector computed tomography (PCD-CT). In measured PCD-CT data, residual stripe amplitudes vary slowly with projection angle, which fixed-bias models cannot adequately capture. We propose TRACE, a two-stage unsupervised sinogram decomposition method for estimating and correcting these response-related errors. TRACE represents stripes as a fixed bias plus low-order discrete cosine transform (DCT) components, using a small number of coefficients to describe angular variations at each detector element. A learnable analysis--synthesis architecture represents the ideal projections, while two-stage optimization separates them from fixed and then dynamic stripes. An angular-gradient soft orthogonality constraint suppresses correlated variations within the shared DCT gradient subspace, reducing the leakage of object structures into the artifact estimate. All parameters are optimized directly on the measured sinogram without paired training data. Experiments on measured QRM mouse phantom and porcine trotter data show that TRACE suppresses ring artifacts and improves image uniformity while preserving edge sharpness, soft-tissue texture, and trabecular detail.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Self-Adaptive Ring Artifact Reduction Method for Spectral Photon Counting CT.IEEE transactions on medical imaging · 2026
- Single-Acquisition Spectral and Ultra-High-Resolution Pediatric Head CT: Phantom Comparison of Deep-Silicon Photon-Counting and Energy-Integrating DetectorsmedRxiv · 2026
- ReCo-Diff: residual-conditioned deterministic sampling for cold diffusion in sparse-view CTPhysics in Medicine and Biology · 2026
- Understanding Photon-Counting CT: Physics, Detector Technology, and Image Reconstructions.Sensors (Basel, Switzerland) · 2026
- Efficiently harvesting low‐energy photons from silicon photon counting detectorsMedical Physics · 2026
- Trans2-CBCT: A Dual-Transformer Framework for Sparse-View CBCT Reconstruction.Sensors (Basel, Switzerland) · 2026