Triple coronal hard X-ray source observed by STIX during a failed filament eruption
Tomasz Mrozek, Marek Stęślicki, Sylwester Kołomański, Krzysztof Barczynski
Key points
From the paper's conclusion- We then used the AIA DEM to predict X-ray emission maps and compared them with STIX images. } {We find temporal and spatial correlations between the failed eruption and HXR sources.
Abstract
{Observations reveal hard X-ray sources in the solar corona with morphologies and locations distinct from typical solar flares. One expected mechanisms for hard X-ray (HXR) production in the solar corona is eruptions of various types. Failed eruptions are promising targets for detecting non-flare-related HXR sources because most of their energy is expected to be dissipated in the corona. } {We investigated the SOL2022-0 to determine the nature of coronal HXR sources associated with the event.} {We used Solar Orbiter's STIX, EUI, and SDO AIA observations. We reconstructed STIX images using the MARLIN algorithm. We used EUI data to cross-check the view of the event from two vantage points. The AIA images enabled kinematic analysis and reconstruction of differential emission measure (DEM) maps. We then used the AIA DEM to predict X-ray emission maps and compared them with STIX images. } {We find temporal and spatial correlations between the failed eruption and HXR sources. During the braking of the filament eruption, we observed non-thermal HXR emission from coronal sources along the path of the eruption. Thermal HXR emission was concentrated in three coronal sources formed with two separate mechanisms: chromospheric evaporation and direct heating. Directly heated sources are the result of the interaction of the eruption with the overlying magnetic field, and were observed to cool for an extremely long time.} {The HXR emission sources related to the interaction between the eruption and the overlying magnetic field might be typical structures in all flares. However, they appear to be weak, since their emission is only 5-20~\% of that from the flare coronal source. If footpoint sources were not occulted, then these weak coronal emission sources would not be visible due to the low dynamic range of HXR telescopes.}
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Solar Soft X-Ray Coronal Dimming in a Failed Eruption Associated with Plasma CoolingThe Astrophysical Journal Letters · 2026
- Hard X-ray flux rope anchor points in the October 2024 X9 flareAstronomy & Astrophysics · 2026
- 3D reconstruction of thermal hard X-ray sources in solar flares from combined STIX and HXI visibilitiesAstronomy and Astrophysics · 2026
- A Failed Filament Eruption and Associated Active Region Heating Driven by External Magnetic ReconnectionarXiv · 2026
- Multiwavelength Study of a Superflare on RS CVn–Type Star HD 22468 Triggered at Hard X-Ray by SVOMThe Astrophysical Journal · 2026
- Probing flare-associated eruptions on AB Doradus via X-ray absorption variations.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2026