Population-Specific Reference Intervals for Whole-Blood GSH/GSSG Ratio in Healthy Emirati Adults According to CLSI and ISO 15189 Guidelines.
Sushma Ravindra Umrao, Sampathkumar Elangovan, Muhammad Raza Qureshi, Muhammad Masoud Alam, Farhan Ashraf, Shafaath Husain Syed Mohammed, Mohamed Sayed Tharammal, Faiz Ul Amin,
Life Core Private Clinic, Abu Dhabi, United Arab Emirates.
Key points
From the paper's conclusion- Manufacturer-provided reference intervals do not reflect the distribution observed in healthy Emirati adults. Population-specific reference intervals are therefore necessary. Reporting both 95% and 90% intervals, supported by bootstrap estimates, enhances clinical interpretation for both diagnostic and screening applications.
Abstract
BACKGROUND: The glutathione redox system, expressed as the ratio of reduced glutathione (GSH) to oxidized glutathione (GSSG), is a key indicator of cellular oxidative status. Manufacturer-provided reference intervals are typically derived from non-local populations and may not be applicable across different ethnic and geographic groups. OBJECTIVE: To characterize the distribution of whole-blood GSH/GSSG ratio in healthy Emirati adults using ultra-high-performance liquid chromatography (UHPLC) and to establish population-specific reference intervals in accordance with CLSI C28-A3 and ISO 15189 guidelines. METHODS: In this cross-sectional study, whole-blood samples from 120 apparently healthy Emirati adults were analyzed using a commercial UHPLC assay. The GSH/GSSG ratio was calculated for each participant. Due to non-normal distribution, reference intervals were derived using a nonparametric approach. Both the conventional 95% reference interval (2.5th-97.5th percentiles) and the central 90% interval (5th-95th percentiles) were calculated. Bootstrap resampling (20,000 iterations) was used to estimate 95% confidence intervals for the central 90% limits. RESULTS: The GSH/GSSG ratio demonstrated a right-skewed distribution with a median (IQR) of 4.76 (3.58-6.77). Most participants (89.2%) had values below the manufacturer-reported reference interval (10-15), with only 5.0% within this range. The nonparametric 95% reference interval was 1.66-28.40. The central 90% interval was 2.53-17.20, with bootstrap 95% confidence intervals of 2.21-2.97 (lower) and 14.92-19.73 (upper). CONCLUSION: Manufacturer-provided reference intervals do not reflect the distribution observed in healthy Emirati adults. Population-specific reference intervals are therefore necessary. Reporting both 95% and 90% intervals, supported by bootstrap estimates, enhances clinical interpretation for both diagnostic and screening applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-338 Analysis of Geographic and Age-Specific Variability in Glucose-6-phosphate Dehydrogenase and its Implications for Reference Intervals: A Multi-Regional StudyClinical Chemistry · 2026
- Population-specific reference intervals for cystatin C, creatinine and urea, and their impact on diagnostic classification and eGFR stratification in Nigerian adults.Clinical biochemistry · 2026
- A-202 Establishing WHO 2022 Normal Male Median–Based Reference Intervals for G6PD Activity in a Large Institutional CohortClinical Chemistry · 2026
- Establishment Reference Intervals Using the Kosmic Algorithm for Hemoglobin Levels and Platelet, Red Blood Cell, and White Blood Cell Counts.Journal of clinical laboratory analysis · 2026
- Evaluation of IgG Subclass Reference Intervals in Koreans Using Indirect Methods Reveals Lower IgG3 Concentrations.Diagnostics (Basel, Switzerland) · 2026
- Verification of reference intervals for routine biochemical tests using the reflimR in Turkish adultsPLoS ONE · 2026