Conditional Flow Matching for Cross-Field MRI Harmonisation
Baris Imre, Aram Salehi, Levente Baljer, Andrew Webb, Marius Staring, Efe Ilicak
Key points
From the paper's conclusion- We phrase the problem as a conditional flow matching path: because the source and target volumes are spatially registered, we learn a velocity field that carries the source slice directly to the target slice, rather than starting from noise.
Abstract
Magnetic resonance images of the same subject look markedly different across field strengths, which complicates the comparison and pooling of data across sites. We address cross-field brain-MRI translation for the MRIxFields2026 challenge, and in particular its Task~3: a single model that translates between any directed pair of the five field strengths and across three contrasts. We phrase the problem as a conditional flow matching path: because the source and target volumes are spatially registered, we learn a velocity field that carries the source slice directly to the target slice, rather than starting from noise. To learn this mapping from only three paired subjects, the unified model is trained in three stages: a degradation-bridge pretraining that distills a restoration prior from the abundant unpaired retrospective cohort, a cross-field finetuning over all directed pairs on the paired cohort, and an adversarial refinement that sharpens the output. At inference, we integrate the learned velocity with a second-order Heun solver in a handful of steps. A restoration prior learned without any paired data already reaches a mean SSIM of 0.837, and each subsequent training stage improves on it. A single 6.3M-parameter model thereby covers all 60 field-pair and contrast combinations, with inference in five solver steps per slice. On the challenge evaluation set the model reaches a mean SSIM of 0.909, averaged over the three contrasts, outperforming regression and diffusion baselines built on the identical network on all three challenge metrics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fast Cross-Strength Multi-Contrast Brain MRI Translation using Latent Bridge MatchingarXiv · 2026
- UniField++: A Unified Agentic Framework with Loop Reasoning for MRI Field-Strength EnhancementarXiv · 2026
- ReCoFlow-MRI: Few-Step Conditional Flow Matching for GNL-Induced Nonlinear MRI ReconstructionarXiv · 2026
- Zero-Shot Brain MRI Inpainting with 2.5D Unconditional Flow PriorsarXiv · 2026
- Unified Multi-plane Autoregressive Diffusion for 3D Multi-contrast MRI SynthesisarXiv · 2026
- A K-space guided invertible diffusion model for accelerating MRI reconstruction.Medical physics · 2026