Design and performance of the Fast Beam Condition Monitor for luminosity and background measurement at the CMS Experiment in LHC Run 3
The CMS BRIL Collaboration, Eliana Acurio, Ying An, Iakov Andreev, Tomas Atehortua, Georg Auzinger, Hamed Bakhshiansohi, Gergely Balint,
Key points
From the paper's conclusion- The Fast Beam Condition Monitor (BCM1F) has been used at the CMS Experiment since the first LHC circulating beams in 2008.
Abstract
The Fast Beam Condition Monitor (BCM1F) has been used at the CMS Experiment since the first LHC circulating beams in 2008. Originally meant as a beam-induced background monitor for fast beam losses detection, it showed a potential also for luminosity measurements in 2012 running, and has been used for luminosity measurements since the beginning of Run 2 data taking in 2015 as a part of the Beam Radiation, Instrumentation and Luminosity (BRIL) system. Over the years, the system has undergone various upgrades to the sensors, the front-end and back-end electronics, providing improvements in the precision of the measurements, that remain valid in the higher pileup conditions of LHC Run 3 (2022-2026). Based on the experience of all BCM1F Run 2 upgrades, the detector was completely rebuilt prior to LHC Run 3 using AC-coupled silicon-pad diodes and active cooling. This latest detector version exhibits excellent linearity with instantaneous luminosity and achieves nanosecond-level timing precision, enabling improved systematic corrections for luminosity and background measurements. This paper presents a detailed overview of the detector system for LHC Run 3, including the selection and qualification of sensors as well as a summary of the readout system. It also outlines the processing and calibration strategy for luminosity data, discussing operational hurdles and comparing BCM1F measurements to other CMS luminosity measurements to assess the system's performance as a luminometer. Lastly, the implications for the design of a future luminosity detector to be used in the envisioned HL-LHC upgrade are discussed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Precision luminosity measurement in proton-proton collisions at a center-of-mass energy of 13 TeV with the CMS detector at the Large Hadron ColliderPhysical Review X · 2026
- CMS ECAL Phase-2 upgrade: characterisation and stability analysis of a three-stage low-voltage power-conversion systemarXiv · 2026
- Absolute luminosity calibration of the LHCb detector in $pp$ collisions at $\sqrt{s} = 13$ TeV with beam-gas imagingarXiv · 2026
- Beam-beam effects on measurements at electron-positron colliders: LEP neutrino counting and Higgs factoriesarXiv · 2026
- Demonstrating CBM Capabilities through $\Lambda$ Reconstruction with mCBMarXiv · 2026
- Impact of Rapid Acceleration on Beam Dynamics in the Rapid-Cycling Synchrotrons of a Muon ColliderarXiv · 2026