Model Effect or Label Effect? Refined Annotations and a Human-Referenced Benchmark for Pulmonary Embolism Segmentation
Qihang Sun, Zhongxiao Liu, Bailiang Jian, Shenman Qiu, Jingyuan Wang, Lei Zhang, Lixiang Xie, Jiazhen Pan,
Key points
From the paper's conclusion- Purpose: To quantify how evaluation annotations influence measured pulmonary embolism (PE) segmentation performance relative to model training changes, and to establish a human-referenced framework.
Abstract
Purpose: To quantify how evaluation annotations influence measured pulmonary embolism (PE) segmentation performance relative to model training changes, and to establish a human-referenced framework. Materials and Methods: This retrospective study screened 166 voxel-annotated CT pulmonary angiography cases from CADPE (n=91), FUMPE (n=35), and READ (n=40); 149 were included. A primary rater annotated PE by protocol, and a senior thoracic radiologist reviewed and revised all segmentations. Three additional raters at three centers annotated a 15-case subset. The label effect was measured by evaluating two pretrained nnU-Net models (nnU-Net-A, nnU-Net-B) against original and refined annotations. The model effect was measured by comparing the same architecture trained on different dataset combinations with annotations fixed. The benchmark model (nnPE) was trained with leave-one-dataset-out and pooled five-fold cross-validation. Four metric categories were analyzed with case-paired Wilcoxon signed-rank tests, Benjamini-Hochberg correction, and bootstrap 95% CIs. Results: Changing only the annotation increased mean DSC by 0.143 (0.122-0.166) for nnU-Net-A and 0.188 (0.163-0.213) for nnU-Net-B (both P < .001), whereas changing training-dataset composition changed DSC by 0.028. The label effect exceeded the model effect on CADPE and FUMPE and was 0.045 on READ. Within-mask attenuation SD fell in all three datasets after re-annotation (all P < .001). nnPE reached DSC 0.72 +/- 0.22 on pooled cross-validation but scored below all four annotators across 52 paired comparisons (all corrected P < .05). Conclusion: Evaluation annotations affected measured PE segmentation performance at least as much as model training choices. A human-referenced evaluation framework is publicly available for future study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Who labels best? Radiologists, rules, or large language modelsfor CT reports on pulmonary embolismEuropean Radiology Experimental · 2026
- Artificial intelligence-enabled detection of vascular perfusion defects on ventilation/perfusion (V/Q) scintigraphy for pulmonary embolism.Physics in medicine and biology · 2026
- PERADS.net: Automated PE-RADS Grading with Named Anatomic Localization and Right-to-Left Ventricular Ratio Measurement on CT Pulmonary AngiographymedRxiv · 2026
- Adapting Echocardiographic Foundation Models for Detecting Pulmonary Embolism-Related Right-Heart StrainmedRxiv · 2026
- When Reference Labels Change: A Framework for Assessing Deep Learning Measurement of Right Ventricular Ejection FractionDiagnostics · 2026
- PatchChestCT: A patch-level spatial annotation dataset for nine abnormalities in chest CT.Scientific data · 2026