arXivPreprintOpen accesscs.CV

Can You Trust Frozen Hematology Foundation Models under Acquisition Shift?

Jai Kumar Sharma, Peeyush Tapadiya

Computational

Key points

From the paper's conclusion
  • We audit 15 frozen encoders (hematology, pathology, and general vision) across four public single-cell acquisition domains along two axes: accuracy robustness and calibration.

Abstract

Frozen hematology foundation-model (FM) embeddings reach near-saturated in-domain white-blood-cell (WBC) accuracy, but clinical deployment demands reliability across scanners, sites, stains and preparation pipelines. We audit 15 frozen encoders (hematology, pathology, and general vision) across four public single-cell acquisition domains along two axes: accuracy robustness and calibration. In-domain linear-probe macro-F1 is saturated (0.98-0.997), yet cross-dataset macro-F1 drops 34-72% and rankings re-order: DinoBloom-L, the in-domain best, falls to 10th of 15 on the most-shifted target (MLL23) at the benchmark's shared 224-px input, behind RedDino and several general and pathology encoders. Rank transfer is probe-dependent: 1-NN retrieval is more stable on average than a source-fitted linear head (median $ρ$ 0.65 vs 0.45), but neither probe universally predicts target robustness. Calibration also collapses: source-trained probes are nearly calibrated in-domain (expected calibration error, ECE, 0.004) but confidently wrong off-domain (ECE 0.35), and source-fitted temperature scaling transfers poorly. We further audit pretraining exposure and identify MLL23 as DinoBloom's internal cohort; because DinoBloom's only held-out dataset is also our source domain, this benchmark cannot isolate exposure from scanner-associated shift. Label-free adaptation and marginal-entropy-based model selection appear safe under balanced evaluation but fail under realistic WBC class-prior shift. Class-Balanced Re-standardization (CBR), a training-free pseudo-label-balanced feature normalization, improves all evaluated target-prior scenario means and partially improves calibration, although encoder-level exceptions and residual miscalibration remain. Hematology FM benchmarks must therefore jointly audit accuracy, calibration, exposure, and class-prior robustness.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Can You Trust Frozen Hematology Foundation Models under Acquisition Shift? — Science Skim