Study of the intrinsic resolution of LaBr3(Ce,Sr) and NaI(Tl) crystals
Peiyi Feng, Xilei Sun, Zhenghua An, Dali Zhang, Xinqiao Li, Shaolin Xiong, Hong Lu
Key points
From the paper's conclusion- We discussed the sources of intrinsic resolution, and the results indicate that the intrinsic resolution of the LaBr3(Ce,Sr) crystal primarily arises from luminescence non-proportionality, while that of the NaI(Tl) crystal mainly stems from fluctuations during energy transfer.
Abstract
The Gravitational wave burst high-energy Elec?tromagnetic Counterpart All-sky Monitor (GECAM) utilizes a large number of LaBr3 and NaI(Tl) crystals as sensitive materials for its gamma-ray detectors. To address the fitting issues of the energy resolution curves in the ground calibration of the GECAM detectors, this work conducts a comprehensive testing and comparative study of the energy resolution of 1-inch LaBr3(Ce,Sr) and NaI(Tl) crystals produced from the same batch. We employed a Hard X-ray Calibration Facility (HXCF), a PMT single-photoelectron calibration system, and Geant4 Monte Carlo simulation tools to quantify seven factors influencing energy resolution. The results indicate that the contributions of various components to energy resolution differ, with pho?toelectron statistical fluctuations and intrinsic resolution being predominant. For 100 keV X-rays, the total energy resolution of the LaBr3(Ce,Sr) crystal is 3.71% \pm 0.03% (expressed as 1-σ), with a contribution from photoelectron statistical fluctuations of 2.69% \pm 0.00% and an intrinsic resolution of 2.45% \pm 0.05%. For 100 keV X-rays, the total energy resolution of the NaI(Tl) crystal is 4.41% \pm 0.14% (expressed as 1-σ), with a contribution from photoelectron statistical fluctuations of 3.20% \pm 0.00% and an intrinsic resolution of 2.90% \pm 0.21%. We discussed the sources of intrinsic resolution, and the results indicate that the intrinsic resolution of the LaBr3(Ce,Sr) crystal primarily arises from luminescence non-proportionality, while that of the NaI(Tl) crystal mainly stems from fluctuations during energy transfer. This study emphasizes precise and specific experimental measurements and comparative research, demonstrating that both factors are important contributors to intrinsic resolution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Broad-energy characterization of MAPD-3NM2 photodiode Matrix coupled with LaBr3(Ce)and YAG:Ce scintillators for space ApplicationsBAKU STATE UNIVERSITY JOURNAL of PHYSICS & SPACE SCIENCES · 2026
- A Review of Defect Formation Mechanisms, Their Impact on Radiation Detection Performance, and Defect Suppression Strategies in Melt-Grown CsPbBr3 Single CrystalsCrystals · 2026
- Theoretical full-energy peak efficiency determination for LaBr3:Ce detectors.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Spectral linearity and acquisition-chain effects in a LaBr3:Ce scintillation detector.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- The Gator low-background spectrometer: readout upgrade and photomultiplier tube radioassay for XLZDarXiv · 2026
- Li+-Induced Enhancement of Excitonic Luminescence in γ-CuBr Single Crystals Grown by the Vertical Bridgman MethodCrystal Growth & Design · 2026