Voltage-to-temperature calibration of the High Altitude THz Solar telescope acquisition system
Gedeane G. S. Kenshima, Daniel R. Sousa, Tiago Giorgetti, Paulo J. A. Simões, C. Guillermo Giménez de Castro
Key points
From the paper's conclusion- Our quantitative results demonstrate high linearity in the system's response over the input source's temperature range, with the Hamming window achieving the highest precision, yielding a Root Mean Square Error (RMSE) of 15.48 and a calibration temperature-to-voltage factor of 10.32 +- 0.13 mV/K.
Abstract
The THz range has been under-explored for solar astronomy, mainly due to technological limitations. Only recently, a few new telescopes, such as the High Altitude Terahertz Solar (HATS) photometer, have been monitoring the solar activity in this range of the spectrum. This paper presents the experimental characterization and voltage-to-temperature calibration of the HATS acquisition system. HATS uses a Golay cell for capturing the incoming radiation, modulated by a 20 Hz fork chopper. The amplitude of the signal is then obtained at predetermined time intervals by applying a windowing function and an FFT to the signal. To characterize this acquisition system, a blackbody calibrator, with temperatures varying from 100 to 500 C (373.15 K to 648.15 K), was used as a THz source, and two signal recovery methodologies were compared: sinusoidal curve fitting and FFT combined with six windowing functions (rectangular, Hamming, Hann, Barlett, Blackman, and Flat Top). Our quantitative results demonstrate high linearity in the system's response over the input source's temperature range, with the Hamming window achieving the highest precision, yielding a Root Mean Square Error (RMSE) of 15.48 and a calibration temperature-to-voltage factor of 10.32 +- 0.13 mV/K. In contrast, the Bartlett window presented the highest error (RMSE 16.02). The choice of windowing function had only a minor effect on the calibration factors, which ranged from 10.32 to 10.43 mV/K, all within the experimental uncertainties. Beyond solar photometry, the signal modulation and windowing concepts established here are highly applicable to other fields requiring high-sensitivity thermal detection, such as industrial pyrometry for high-temperature manufacturing, environmental monitoring of atmospheric water vapor, and the development of medical imaging systems based on Terahertz radiation for non-invasive tissue analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental study of a TEA CO 2 laser-pumped CH 3 F molecular terahertz laser operating at 231 μ mLaser Physics · 2026
- Robust Bayesian parameter estimation for spectral encoded single-shot THz spectroscopy.Optics express · 2026
- Performance analysis of a Rydberg atom THz radiometer conceptarXiv · 2026
- Terahertz photonic heterodyne spectral analysis with (sub-) kHz resolution and 6.5 THz frequency coverageNature Communications · 2025
- Ultrasensitive and High‐Speed Room‐Temperature Sub‐Terahertz Photothermoelectric Detectors: Antenna‐Graphene Hybrid Plasmon and Microcavity EffectsLaser & Photonics Reviews · 2026
- Longitudinally resolved temperature measurement in diode-pumped alkali lasers via dual-wavelength CH4 absorption spectroscopy with one-step fitting.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026