Effects of Hybrid Copper Oxide-Silver and Titanium Dioxide-Silver Nanocoatings on the Surface Roughness and Friction of Stainless Steel Orthodontic Brackets: A Comparative In Vitro Study.
Devireddy Alekhya, Panaka Padma Prathyusha, Greeshma M Harini, Perala Johnson, Uday Kumar Digumarthi, Ganugapanta Vivek Reddy, Gowri Sankar Singaraju, Prasad Mandava
Orthodontics and Dentofacial Orthopedics, Narayana Dental College and Hospital, Nellore, IND. · Orthodontics and Dentofacial Orthopedics, Care Dental College, Guntur, IND.
Key points
From the paper's conclusion- Roughness increased in all groups after friction testing (t(9) ≥ 33.48, p < 0.001), with smaller increases in the coated groups.
Abstract
Introduction Nanoparticle coatings on orthodontic brackets have antibacterial potential but may alter surface roughness and friction at the bracket-archwire interface. This study compared the surface roughness and static frictional resistance of stainless steel brackets coated with silver-impregnated copper oxide (CuO+Ag) or silver-impregnated titanium dioxide (TiO₂+Ag) nanoparticles with those of uncoated brackets. Materials and methods Thirty stainless steel maxillary central incisor brackets (0.022-inch slot) were allocated into three groups (n = 10 each): uncoated control, CuO+Ag-coated, and TiO₂+Ag-coated. Arithmetic average roughness (Ra), root mean square roughness (Rq), and maximum peak-to-valley height (Rz) were measured by atomic force microscopy as received (T0), after coating (T1), and after friction testing (T2). Static friction was measured using a universal testing machine with a 0.019 × 0.025-inch stainless steel archwire in artificial saliva. Data were analyzed using one-way or Welch analysis of variance with post hoc tests and paired t-tests (p < 0.05). Results Baseline roughness was comparable among the groups. At T1, CuO+Ag increased Ra, Rq, and Rz, whereas TiO₂+Ag increased Ra and Rq but decreased Rz (paired t-test, |t(9)| ≥ 10.82, p < 0.001). Static friction differed among the groups (F(2, 27) = 9.15, p < 0.001, η² = 0.404). CuO+Ag showed the lowest friction (36.31 ± 3.90 gf), significantly lower than the control (41.65 ± 4.77 gf; q = 3.82, p = 0.031) and TiO₂+Ag (44.65 ± 4.53 gf; q = 5.97, p < 0.001), whereas TiO₂+Ag did not differ from the control (q = 2.15, p = 0.298). Roughness increased in all groups after friction testing (t(9) ≥ 33.48, p < 0.001), with smaller increases in the coated groups. Conclusions Both nanocoatings altered bracket surface roughness. CuO+Ag significantly reduced static frictional resistance and appears promising for further investigation as an orthodontic bracket coating.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of cytotoxicity, antibacterial activity and surface roughness, among Ag-, Ag/ZnO-, and Ag/TiO2-coated stainless-steel orthodontic brackets: An in vitro study.International orthodontics · 2026
- Antibacterial Interventions for Orthodontic Appliances; Surface Modifications, Coatings and Bulk-Incorporated Antibacterial Agents: Materials, Mechanisms and Clinical Application-A Scoping Review.Materials (Basel, Switzerland) · 2026
- Multifunctional nanosilver-reinforced biocomposite coatings for metallic surface protectionExperimental and Theoretical NANOTECHNOLOGY · 2026
- Effect of Ag nanoparticles on the tribological response of MAO coatings fabricated on plastically deformed titaniumWear · 2026
- Formation and Antibacterial Mechanisms of Micro-Arc Oxidation Coatings on Ta2 Pure Titanium by Doping with Cu2O Nanoparticles.Materials (Basel, Switzerland) · 2026
- Silver Ion Implantation into Orthodontic Stainless-Steel Materials: Physicochemical Characterization and In Vitro Microbiological Evaluation.Journal of functional biomaterials · 2026