Key points
From the paper's conclusion- We examine how the hazards of the cardiac catheterisation laboratory differ from those of the operating theatre and propose a structured six-step approach to the management of a spinal cord stimulator during TAVI.
Abstract
Spinal cord stimulation (SCS) is an established treatment for chronic neuropathic pain, and patients with an implanted stimulator are presenting with increasing frequency for transcatheter aortic valve implantation (TAVI). We describe an 88-year-old man with a high-frequency (10 kHz) spinal cord stimulator for chronic back pain who underwent transfemoral TAVI under sedation for severe symptomatic aortic stenosis. After consultation with the implanting pain service, the stimulator was switched off with the patient's own remote control, which was kept in the procedure room; rapid ventricular pacing was delivered through a bipolar right ventricular lead so that the pacing current was confined to the myocardium and remote from the pulse generator; and external defibrillator pads were positioned away from the generator and the course of the leads. The procedure was uneventful. The patient tolerated the interruption of therapy without clinically significant pain; a new left bundle branch block after valve deployment was identified on an artefact-free trace, stimulation was resumed after the procedure with analgesia equivalent to baseline, and subsequent interrogation confirmed normal device function. The case illustrates the application of a precautionary strategy informed by manufacturer labelling and analogous evidence; because the stimulator was off throughout, it does not establish that any individual measure was necessary. We examine how the hazards of the cardiac catheterisation laboratory differ from those of the operating theatre and propose a structured six-step approach to the management of a spinal cord stimulator during TAVI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-Term Clinical Outcome and Safety of BurstDR© Spinal Cord Stimulation in a Patient with a Permanent Cardiac Pacemaker-Defibrillator: A Case Report.Journal of clinical medicine · 2026
- ECAP-Guided Closed-Loop Spinal Cord Stimulation for Axial Thoracic Pain: A Case Report.Clinical case reports · 2026
- Safe Implementation of Spinal Cord Stimulation in a Patient With a Ventriculoperitoneal Shunt: A Case Report and Review of Procedural Considerations.Pain medicine case reports · 2026
- Simultaneous Percutaneous Spinal Cord Stimulation Lead Placement During Spine Surgery.NeuroSci · 2026
- Perioperative Management of an Implanted Spinal Cord Stimulator: A Problem-Based Learning Discussion.A&A practice · 2026
- Cardiovascular and autonomic responses to transcutaneous spinal cord stimulation combined with activity-based therapy after chronic spinal cord injury: An exploratory study from the MACHINE trialmedRxiv · 2026