Very Early-Onset Prosthetic Valve Endocarditis Following Transcatheter Aortic Valve Implantation Complicated by an Aorto-Left Atrial Fistula and Aortic Root Pseudoaneurysm.
Giulio D'Ascoli, Jesús Piqueras-Flores, Carlos Sánchez Sánchez, Fernando Lozano Ruiz-Poveda
Interventional Cardiology Unit, Hospital General Universitario de Ciudad Real, Ciudad Real, ESP. · Clinical Cardiology Unit, Hospital General Universitario de Ciudad Real, Ciudad Real, ESP.
Key points
From the paper's conclusion- We report the case of an 81-year-old man who underwent transfemoral TAVI with a self-expanding Evolut FX valve for severe symptomatic aortic stenosis.
Abstract
Transcatheter aortic valve implantation (TAVI) is an established treatment for severe aortic stenosis. Infective endocarditis (IE) is an uncommon but potentially devastating complication, typically presenting weeks to months after valve implantation. Very early-onset prosthetic valve endocarditis (PVE), occurring within 48 hours of implantation, poses a particular diagnostic challenge, as infectious complications must be distinguished from procedure-related structural injury and sterile postprocedural inflammatory changes. We report the case of an 81-year-old man who underwent transfemoral TAVI with a self-expanding Evolut FX valve for severe symptomatic aortic stenosis. The procedure was uneventful, with satisfactory immediate angiographic and echocardiographic findings. Within 48 hours, the patient developed fever and elevated inflammatory markers. Two independent blood culture sets were positive for methicillin-susceptible Staphylococcus aureus (MSSA). Fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) demonstrated increased metabolic uptake at the aortic root. Given the early postprocedural timing, this finding was interpreted cautiously, as sterile inflammatory changes could not be excluded. Subsequent transesophageal echocardiography (TEE) revealed a prosthetic valve vegetation, an aortic-root pseudoaneurysm, and an aorto-left atrial fistula with continuous shunt flow. The combination of microbiological and echocardiographic findings fulfilled the diagnostic criteria for definite prosthetic valve IE. Surgical intervention was considered prohibitive by the multidisciplinary Heart Team, and antimicrobial treatment was administered. Despite treatment, the patient's clinical condition rapidly deteriorated, resulting in death within one week of diagnosis. This case highlights the importance of integrating clinical and microbiological findings with multimodality imaging in diagnosing very early-onset PVE, while carefully considering potential procedure-related structural injury.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Non-ST-Segment Elevation Acute Coronary Syndrome From Transcatheter Aortic Valve Replacement Infective Endocarditis Embolization.JACC. Case reports · 2026
- Prosthetic Aortic Valve Infective Endocarditis Complicated With Malignant Arrhythmias: Diagnostic and Management Challenges.Cureus · 2026
- Surgical Explantation of a Balloon-Expandable Transcatheter Aortic Valve With Aortic Root Preservation for Prosthetic Valve Endocarditis: A Case Report.Cureus · 2026
- Infective endocarditis following transcatheter valvular interventions (transcatheter aortic valve implantation and transcatheter edge-to-edge repair).Kardiologia polska · 2026
- A Case of Nontuberculous Mycobacterial Prosthetic Valve Endocarditis.Spartan medical research journal · 2026
- When Imaging Deceives: Recurrent Thromboembolic Strokes From Polymicrobial Bioprosthetic Valve Infection With Repeatedly Negative Transesophageal Echocardiography.Cureus · 2026