Ripple-Like Descemet Membrane Folds Following Combined Microhook Ab Interno Trabeculotomy and Cataract Surgery: A Case Report.
Hinako Ohtani, Takayuki Naito, Yoshichika Wanami, Chisako Ida, Takuro Shimoji, Keigo Takagi, Yuto Yoshida, Masaki Tanito
Department of Ophthalmology, Shimane University Faculty of Medicine, Izumo, JPN.
Key points
From the paper's conclusion- We report a case of distinctive ripple-like Descemet membrane folds after combined microhook ab interno trabeculotomy (µLOT) and cataract surgery.
Abstract
We report a case of distinctive ripple-like Descemet membrane folds after combined microhook ab interno trabeculotomy (µLOT) and cataract surgery. A 70-year-old Japanese man with primary open-angle glaucoma and cataract underwent nasal µLOT followed by phacoemulsification and intraocular lens implantation in the right eye. At 1 week postoperatively, unusual ripple-like Descemet membrane folds, which had not been noted at the examination on postoperative day 1, were observed in the inferior cornea with localized corneal edema. Best-corrected visual acuity was 0.4 in decimal notation. Multimodal imaging revealed no apparent Descemet membrane detachment or tears. Review of the surgical video showed inadvertent aspiration of the Descemet membrane during irrigation/aspiration (I/A), followed by the appearance of the folds. The patient was managed conservatively, and the folds resolved completely by 3 months postoperatively, with best-corrected visual acuity improving to 1.2. We hypothesize that incision of peripheral supporting structures during µLOT may have reduced tangential tension in the Descemet membrane, increasing its susceptibility to aspiration during subsequent I/A. This mechanism remains unconfirmed. Careful I/A manipulation following µLOT is warranted, and conservative management may be appropriate for similar folds without associated Descemet membrane detachment or tears. As minimally invasive glaucoma surgery is often performed by ophthalmology trainees and surgeons with limited surgical experience, this report may serve as an educational example of an intraoperative complication during combined surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intraoperative OCT observation of incision-related descemet membrane detachment during implantable collamer lens implantation.Frontiers in medicine · 2026
- Characteristics and Factors of Incision-Related Descemet Membrane Detachment During Cataract Surgery: A Prospective Study.Ophthalmology and therapy · 2026
- Intraoperative Quantification of Incision-Site Descemet Membrane Detachment During Phacoemulsification: A Paired-Eye Comparison of Longitudinal and Torsional Ultrasound.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Descemet membrane detachment during phacoemulsification. A Review.Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia · 2026
- Treatment of Refractory Descemet Membrane Detachment via Repeat Descemetopexy: A Case Report.Journal of visualized experiments : JoVE · 2026
- Refractive and Corneal Astigmatism After Implantation of a Supraciliary Drainage Device in Microinvasive Glaucoma SurgeryJournal of Refractive Surgery · 2026