Macroenzymes in Isolated Hyperenzymemia: Detection Methods and Decision Thresholds for Polyethylene Glycol-Precipitable Activity.
Lukasz Kopoczynski, Adam Lasota, Dorota Bartkowiak, Kamil Boguszewski, Michal Wiesner, Bartlomiej Jakubczyk, Lukasz Wodzinski
Medicine, Polish Red Cross Maritime Hospital, Gdynia, POL. · Cardiology, Pope John Paul II Regional Hospital, Zamosc, POL.
Key points
From the paper's conclusion- Storage at 4°C, used as a lower-cost alternative, is not reliable either, since enzyme activity sometimes remains unchanged despite the presence of a macroenzyme.
Abstract
Macroenzymes, such as macroamylase, macro-aspartate aminotransferase (macro-AST), and macro-creatine kinase (macro-CK), are high-molecular-weight complexes formed when serum enzymes bind to immunoglobulins or other plasma components, or undergo self-polymerization. These complexes can artificially inflate results in routine activity assays, producing a picture of isolated hyperenzymemia, such as isolated AST elevation, and are sometimes the reason for costly, occasionally invasive diagnostic workup. A common screening method is polyethylene glycol (PEG) precipitation, where the result is reported as PEG-precipitable activity, with the percentage of activity precipitated by PEG (%PPA), and evaluated against a decision threshold. This review examines the heterogeneity of %PPA decision thresholds and of the alternative detection methods and assesses how consistently these criteria are applied in practice. The analysis covers the literature published from March 2021 onward, supplemented by iterative backward citation searching, which brought in the earlier studies that established the %PPA thresholds, and by forward citation searching of those studies. The thresholds compared here vary substantially for the same enzyme, with the widest discrepancies in CK. The differences stem from variations in assay platforms, reference populations, the statistical cut-offs adopted, and the precipitation protocol itself, so the thresholds are not transferable between laboratories. Within that protocol, polymer concentrations remain relatively uniform, while incubation times, centrifugation conditions, and reference materials differ substantially from report to report. Storage at 4°C, used as a lower-cost alternative, is not reliable either, since enzyme activity sometimes remains unchanged despite the presence of a macroenzyme. Reported detection rates vary by several orders of magnitude, reflecting the degree of preselection of the study group rather than the frequency of the macroenzyme itself. A negative result from PEG precipitation or from storage at 4°C therefore does not rule out a macroenzyme. Because a %PPA value depends on the protocol, the platform, and the control sample assayed in parallel, standardized reporting of these variables is needed before the results of macroamylase, macro-AST, and macro-CK can be compared between laboratories.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Solving the mystery of persistent isolated aspartate aminotransferase elevation: Macro-AST as a decisive diagnostic consideration.Frontiers in cellular and infection microbiology · 2026
- Interference by macro-B12: multicenter evaluation of polyethylene glycol precipitation and establishment of reference intervals using four different immunoassay methodsAdvances in Laboratory Medicine / Avances en Medicina de Laboratorio · 2026
- Macrohormones in endocrinology: prevalence, clinical impact, and diagnostic approaches.Frontiers in endocrinology · 2026
- Optimization of PEG precipitation for macroprolactinemia screening.Clinical chemistry and laboratory medicine · 2026
- A-022 PREVALENCE OF MACROTROPONIN I IN SINGAPORE: a preliminary analysisClinical Chemistry · 2026
- Establishment of Sex-Specific Reference Intervals for Total and Post-PEG Prolactin on an Automated Analyzer.The journal of applied laboratory medicine · 2026