A Cost-Effective, Kit-Free Method for Extracting Nuclear and Mitochondrial DNA From Low-Abundance Cells in Urine Samples.
Yoshitaka Yamaguchi, Koichi Yamaguchi, Hiroshi Suzuki, Junko Nomoto, Hironori Katayama
Department of Medical Technology and Sciences, School of Health Sciences at Narita, International University of Health and Welfare, Narita, JPN. · Department of Medical Technology, Faculty of Medical and Health Sciences, Tsukuba International University, Tsukuba, JPN.
Key points
From the paper's conclusion- This study evaluates a simplified, cost-effective DNA extraction protocol using only 10% sodium chloride (NaCl) and Proteinase K (ProK) to isolate both nuclear DNA (nuDNA) and mitochondrial DNA (mtDNA) from low-abundance cells in human urine, providing an open-source alternative to expensive commercial kits.
Abstract
This study evaluates a simplified, cost-effective DNA extraction protocol using only 10% sodium chloride (NaCl) and Proteinase K (ProK) to isolate both nuclear DNA (nuDNA) and mitochondrial DNA (mtDNA) from low-abundance cells in human urine, providing an open-source alternative to expensive commercial kits. Urine samples from six healthy participants were centrifuged, washed with phosphate-buffered saline, lysed with the NaCl/ProK mixture at 60°C overnight, and recovered via ethanol precipitation. To validate downstream applicability, polymerase chain reaction (PCR) amplification was performed targeting the nuclear FGFR3 (423 bp) and the mitochondrial D-loop regions (HV-1: 634 bp, HV-2: 520 bp), followed by agarose gel electrophoresis and Sanger sequencing. The extracted DNA concentrations ranged from undetected to 146.0 μg/mL. PCR amplification of the nuclear FGFR3 succeeded in five out of six samples (83.3%), while the mitochondrial regions (HV-1 and HV-2) achieved a 100% success rate, yielding robust bands even in the sample with undetectable initial genomic DNA. Sanger sequencing and Basic Local Alignment Search Tool search confirmed 100% (FGFR3), 99.4% (HV-1), and 97.8% (HV-2) homology with reference sequences (National Center for Biotechnology Information: NC_012920.1). In conclusion, sequence-ready nuDNA and mtDNA can be successfully extracted using this minimal-reagent, kit-free method. The significantly higher sensitivity of mtDNA highlights its potential for non-invasive genetic diagnostics and point-of-care liquid biopsy in low-biomass specimens.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Urinary DNA Extraction in Uro-Oncology and Selected Non-Urological Malignancies: A Narrative Review.Journal of clinical medicine · 2026
- Protocol for Duplex Sequencing of Mitochondrial DNA in Single Human Oocytes.Journal of visualized experiments : JoVE · 2026
- Nature-Inspired Histidine and Guanidine Modification of Magnetic Nanoparticles for Urinary DNA Liquid Biopsy.Small methods · 2026
- Development of an Oxford nanopore sequencing technology-based whole genome sequencing method for Plasmodium falciparum to support malaria molecular surveillanceScientific Reports · 2026
- Nanomito enables amplification-free full-length analysis of mitochondrial DNA variants and deletionsScientific Reports · 2026
- Effect of Storage Conditions on Equine Herpesvirus-1 DNA Detection in Equine UrineAnimals · 2026