Temporary Left Ventricular Unloading With Impella as a Bridge to Emergency Surgery for Acute Mitral Bioprosthetic Failure.
Osamu Kinoshita, Takuma Aoki, Satoru Murata, Kento Murohara, Wataru Iai
Department of Cardiovascular Surgery, National Hospital Organization Saitama Hospital, Wako, JPN. · Department of Cardiology, National Hospital Organization Saitama Hospital, Wako, JPN.
Key points
From the paper's conclusion- When definitive surgery for acute left-sided valvular failure must be delayed for logistical reasons, temporary left ventricular unloading may be considered as a means of protecting the lung during the wait.
Abstract
Structural valve deterioration usually declares itself gradually, but a bioprosthetic leaflet that tears away from a stent post can produce catastrophic regurgitation without warning. In the mitral position, the left atrium has not had time to become compliant, and the resulting rise in pulmonary capillary pressure can flood the lungs within hours. A 68-year-old woman who had undergone mitral valve replacement with a bovine pericardial bioprosthesis 13 years earlier developed sudden dyspnea. Her oxygen saturation was 58%, the chest radiograph showed almost complete bilateral opacification, and the pH was 7.042 with a lactate of 8.8 mmol/L. She was intubated after noninvasive ventilation failed. Catheterization excluded coronary disease and showed a cardiac index of 1.32 L/minute/m², a mean pulmonary artery pressure of 35 mmHg, and a wedge pressure of 22 mmHg. Echocardiography demonstrated severe regurgitation through the prosthesis with an abnormally mobile leaflet. Emergency surgery was indicated, but the operating room was occupied, and a wait of several hours was expected. With the pulmonary artery pressure rising, an Impella CP (Abiomed, Danvers, MA) was implanted approximately 11 hours after arrival and supported the circulation for five hours until cardiopulmonary bypass was established. During that interval, the rise in pulmonary artery pressure did not continue; the cardiac index and mixed venous oxygen saturation increased, and oxygenation was maintained despite a reduction in the fraction of inspired oxygen. Mean pulmonary artery pressure nevertheless remained approximately 40 mmHg. One leaflet was found torn away from a stent post and prolapsing into the left atrium; the valve was replaced with a porcine bioprosthesis. Postoperatively, she required hemodiafiltration for acute kidney injury and temporary pacing for bradyarrhythmia; the course was further complicated by small cerebral infarcts and a right phrenic nerve palsy. She was extubated on day 10 and discharged home on day 48, remaining in New York Heart Association class I at review on day 108. When definitive surgery for acute left-sided valvular failure must be delayed for logistical reasons, temporary left ventricular unloading may be considered as a means of protecting the lung during the wait. In this patient, it was associated with maintained oxygenation and improved systemic hemodynamics, although its independent contribution cannot be determined from a single case.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical applications of Impella 5.5 for acute severe bioprosthetic aortic regurgitation: a bridge to destination therapy report-case series and review.European heart journal. Case reports · 2026
- Rescue transseptal percutaneous mitral balloon valvuloplasty for early bioprosthetic mitral valve thrombosis during VA-ECMO support: a case report.European heart journal. Case reports · 2026
- Physiological Effects and Clinical Limitations of Impella-Bridge Strategy for Post-Infarction Ventricular Septal Rupture.Artificial organs · 2026
- Combined veno-venous ECMO and direct aortic impella 5.5 support enabling emergency mitral valve replacement in acute severe mitral regurgitation with fulminant pulmonary edema.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2026
- Preemptive Transvalvular Mechanical Circulatory Support is Safe and Feasible in High-Risk Cardiac Surgery Patients: Results of IMPACT.The Journal of thoracic and cardiovascular surgery · 2026
- Concomitant Wire-Loop Repositioning and Transapical Valve Replacement for a Migrated Sutureless Aortic Valve.JACC. Case reports · 2026