N-terminal Pro-B-Type Natriuretic Peptide (NT-proBNP) Versus Artificial Intelligence-Enabled Electrocardiography for the Diagnosis of Acute Heart Failure in Emergency Departments: A Systematic Review.

Lamyaa A Elhassan, Mohamed Abdelrahman Mohamed Ali, Elamein Yousif, Mahmoud Abdelghany Eldyasty Ahmed Eid, Hiba Elsadig Abdelmonim Ahmed, Nada Fathi F Mohanmed Ahmed Hamid, Asmaa Fadlallah Hammad Atroun, Mohamed Mahmoud Ismaeel Mohamed,

Basic Medical Sciences, Jazan University, Jazan, SAU. · Internal Medicine, Portiuncula University Hospital, Ballinasloe, IRL.

Review

Key points

From the paper's conclusion
  • N-terminal pro-B-type natriuretic peptide (NT-proBNP) is the guideline-endorsed biomarker for diagnosing acute heart failure (AHF) in the emergency department (ED), while artificial intelligence-enabled electrocardiography (AI-ECG) has emerged as a rapid, phlebotomy-free alternative.

Abstract

N-terminal pro-B-type natriuretic peptide (NT-proBNP) is the guideline-endorsed biomarker for diagnosing acute heart failure (AHF) in the emergency department (ED), while artificial intelligence-enabled electrocardiography (AI-ECG) has emerged as a rapid, phlebotomy-free alternative. AI-ECG models are trained end-to-end on raw waveform or ECG image data and learn subtle depolarisation, repolarisation and conduction features that are not recognisable by conventional criteria; most were trained to detect left ventricular systolic dysfunction (LVSD) rather than the AHF syndrome itself. Their relative performance has not been systematically appraised. Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020, four databases were searched from January 2020 to August 2026 for original primary studies reporting the diagnostic accuracy of NT-proBNP and/or AI-ECG for AHF, or its structural correlate LVSD, in adult ED patients. Full database-specific search strategies are reported. Risk of bias was assessed with Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) and reporting completeness of the artificial intelligence studies with the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) 2024. Heterogeneity in target conditions, thresholds and reference standards precluded meta-analysis, and comparisons were classified a priori as direct (within-cohort) or indirect (between-study). Eleven studies comprising more than 40,000 ED encounters were included. NT-proBNP discriminated adjudicated AHF consistently across large prospective cohorts (area under the curve (AUC) 0.87-0.92), with excellent rule-out performance at 300 pg/mL (sensitivity 96%-99%, negative predictive value 95%-98%) but modest specificity (54%-56%). AI-ECG achieved AUCs of 0.88-0.94, highest for LVSD rather than adjudicated AHF, and exceeded NT-proBNP in all four direct within-cohort comparisons (0.89 vs 0.80; 0.91-0.92 vs 0.75). In contrast to the standardised NT-proBNP decision limits, only three of seven AI-ECG studies reported an explicit operating threshold, and the models were trained on four different target labels. Eight studies were at low and three at high risk of bias. CLAIM appraisal showed complete reporting of study design and evaluation but incomplete reporting of model specification, data partitioning and data availability. NT-proBNP remains the better-validated test for adjudicated AHF and retains unmatched rule-out value, whereas AI-ECG offers faster and cheaper detection of structural substrate. Because no study compared the two tests against an adjudicated AHF reference standard, they appear complementary rather than interchangeable, and prospective head-to-head and outcome-based studies are required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers