The compromise between accuracy and computational cost: system requirements of a markerless motion analysis tool for workload monitoring in tennis.
Julie Emmerson, Laurie Needham, Sean Williams, Steffi Colyer
Department for Health, University of Bath, Bath, United Kingdom.
Key points
From the paper's conclusion- Within the conditions examined, reducing the number of cameras or resolution was not an option due to inaccuracies of the open-source pose estimation algorithm, but utilising a lower frame rate appears to offer a promising compromise between computational efficiency and measurement accuracy, potentially increasing the viability of markerless motion capture as a solution for in-field workload monitoring.
Abstract
BACKGROUND: Markerless motion capture can provide a novel method for workload monitoring in tennis, with mechanical work (external and internal components) previously presented as a suitable metric. However, markerless methods typically involve large amounts of raw data and long data processing times, hence this is currently an impractical solution. Therefore, this study investigated the effects of reducing system specifications, with the aim of finding a compromise between computational cost and accuracy that is suitable for use in applied settings. METHODS: Video data of 15 tennis players completing an on-court fatiguing protocol were processed with a markerless motion analysis pipeline (based on open-source pose estimation) to calculate mechanical work. Eight cameras operating at a frame rate of 200 Hz and 1,920 × 1,080 resolution were used. Data were reprocessed using fewer cameras, lower frame rates and lower resolutions. RESULTS: Reducing the number of cameras, even by one, or resolution resulted in large drop-offs in performance, related to erroneous initial pose estimation, with root mean squared differences (RMSD) of ∼160% (external) and ∼150% (internal) when using four cameras and ∼640% (external) and ∼190% (internal) when using quarter resolution videos. Conversely, frame rates of 50 and 100 Hz were deemed acceptable for calculating external (RMSD: 1.4%) and internal (RMSD: 0.9%) work respectively. Reducing the frame rate was also associated with the largest reduction in computational cost, with data saving and processing times approximately proportional to the number of frames. CONCLUSION: Within the conditions examined, reducing the number of cameras or resolution was not an option due to inaccuracies of the open-source pose estimation algorithm, but utilising a lower frame rate appears to offer a promising compromise between computational efficiency and measurement accuracy, potentially increasing the viability of markerless motion capture as a solution for in-field workload monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Markerless Motion Capture in Sport and Exercise: A Systematic Review of Applications, Validity, and ReliabilityApplied Sciences · 2026
- Assessing the accuracy of in-stadium and portable multi-camera markerless motion capture for baseball pitching kinematics and kineticsJournal of Sports Sciences · 2025
- Measurement Boundaries of Single-Camera Markerless Analysis During Early Sprint AccelerationApplied Sciences · 2026
- Agreement of markerless and marker-based joint kinetics in team sport-specific change-of-direction movementsScientific Reports · 2026
- Concurrent Validation of a Multi-Camera Markerless Motion Capture System Against Inertial Sensors for Upper- and Lower-Limb Joint Kinematics.Sensors (Basel, Switzerland) · 2026
- Assessing Sprint Mechanical Outputs Derived from LPS, Radar and Laser Technologies in Basketball.Sensors (Basel, Switzerland) · 2026