Biased and variable: pictorial blood loss estimates from photographs of used menstrual pads compared with alkaline hematin
A. N. Apsey, A. Awais, D. Burnett
Key points
From the paper's conclusion- How accurate and how variable are lay raters' estimates of menstrual blood loss when they apply a pictorial blood loss assessment chart (PBLAC) to photographs of used pads?
Abstract
STUDY QUESTION: How accurate and how variable are lay raters' estimates of menstrual blood loss when they apply a pictorial blood loss assessment chart (PBLAC) to photographs of used pads? SUMMARY ANSWER: Raters captured only about 62% of the blood measured by alkaline hematin, classified only 47.1% of their ratings of heavy cycles as heavy and gave estimates that varied substantially between raters and between sessions. WHAT IS KNOWN ALREADY: Pictorial charts are widely used to estimate menstrual blood loss, but their accuracy against alkaline hematin varies, and it is unclear how consistently different people score the same product. STUDY DESIGN, SIZE, DURATION: Cross-sectional online study of reliability and agreement with a repeated assessment, conducted in November 2026 according to a written protocol. PARTICIPANTS/MATERIALS, SETTING, METHODS: Sixty-nine women recruited through social media rated photographs of the same 117 used pads from eight cycles of a validation study in which every pad had been measured by alkaline hematin, and 44 repeated the ratings about 2 weeks later. The pad users' own in-hand scores served as a comparator. MAIN RESULTS AND THE ROLE OF CHANCE: Raters' cycle estimates captured 62% (95% CI 60-65%) of the alkaline hematin volume (mean bias -44.1 ml; 95% limits of agreement -100.5 to +12.3 ml), and sensitivity for heavy menstrual bleeding (>80 ml) was 47.1%. Choosing the picture closest to each pad's alkaline hematin volume would have produced a shortfall equal to 58% of the raters' shortfall, and the users' in-hand scores were also low (mean bias -38.2 ml). Krippendorff's alpha was 0.86 (95% CI 0.82-0.89) and the test-retest intraclass correlation 0.90, but in absolute terms raters' estimates of the same cycle had a pooled between-rater SD of 18.4 ml (up to 32.1 ml for a single cycle); among the 44 raters who repeated the task, the within-rater SD was 10.7 ml, and 6% of classifications changed on retest. LIMITATIONS, REASONS FOR CAUTION: A limited number of cycles were chosen from the original study to represent different cycle volumes; had other cycles been chosen, the results might have been better or worse. All pads were of one brand, only two cycles were not heavy, and raters scored photographs rather than handling pads. WIDER IMPLICATIONS OF THE FINDINGS: With the pictogram evaluated here, scoring of pad photographs systematically underestimated blood loss, partly because of the chart's fixed picture volumes, and estimates of the same cycle differed by tens of millilitres between raters and between sessions. High agreement statistics should not be taken as evidence that a chart accurately identifies blood loss above 80 ml per cycle. STUDY FUNDING/COMPETING INTEREST(S): This study was funded by the Eunice Kennedy Shriver National Institute of Child Health and Human Development of the National Institutes of Health (NIH grant R44HD102235-03, awarded to TheraNova). A.Aw. and D.B. are co-founders of Quantiflow, which develops image-based methods for measuring menstrual blood loss, including the algorithm evaluated in the source study of the photographs used here. Quantiflow currently operates as a project of TheraNova, which holds the NIH grant that funded this study. Quantiflow is expected to be incorporated as an independent company in which A.Aw. and D.B. will hold equity. A.Aw. and D.B. have been compensated by TheraNova within the past 36 months. D.B. is a named inventor on a pending patent application related to Quantiflow's image-analysis algorithm. All other authors declare no competing interests. TRIAL REGISTRATION NUMBER: N/A.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of visually estimated blood loss in the operating room: a simulation studyBMC Anesthesiology · 2026
- Methods used by health care professionals to quantify blood loss during vaginal birth: a scoping review.Midwifery · 2026
- Performance of quantitative and graduated estimated blood loss in detection of postpartum hemorrhage after spontaneous vaginal delivery.Pregnancy (Hoboken, N.J.) · 2026
- Comparison of an automated and paper bladder diary in pediatric patients: mixed-methods, randomized crossover study.Frontiers in pediatrics · 2026
- Acceptability, Appropriateness and Feasibility of a Calibrated Obstetric Blood Collection Drape for Postpartum Haemorrhage Detection: A Qualitative Study in Two Tertiary-Care hospitals in Delhi, IndiamedRxiv · 2026
- Circular validation in diagnostic research: re-examination of a widely cited study on primary hemostasis screening.Frontiers in medicine · 2026